Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
motor coupling weld broken
Removed four screws from ice maker motor/light support.Then unplugged electrical plug from side of freezer.Used two slip joint pliers to remove coupler from motor shaft. installed new coupler to shaft hand tight as will tighten as motor is run.Then reversed tear down order. Ice dispenser works better than when we first got the refrigerator
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
I removed the Ice door front cover on freezer door. Found door pivot was broken. I installed door pivot bracket, and dashpot in kit. I used most of the kit to repair it. The door now works like new. Thanks for the right parts Frank
Removed six screws from cover in the back of the freezer. Removed old fan . Removed power wires from old motor. Unclipped old motor from the mounting bracket. Replaced old motor and reversed the rest of the parts. Done
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door failing to close without being pushed shut
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge. No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
Just a trickle of water to icemaker and water dispenser
Turned refrig off, pulled it out for access to the valve, unplugged refrig and turned off water supply to the outlet valve. I made the installation a bit more difficult by over tightening the supply line connection which ruined the brass compression washer. I replaced it with a plastic compression washer which is probably better since the supply line is plastic. The electrical connections were very simple. I was just guessing the old outlet valve was bad since I had checked the filter. After replacing the valve, the ice maker and water dispenser work like new on a 17 year old refrigeration. Also, I was very pleased with fast processing and delivery of the order.
At their site was ordering each piece by # and cost and it was adding up to be costly. Went to partselect and was doing the same and up pops the ice door kit. Was a little wary because my original had a heater tape to it. Got the kit and installed not a problem at all. 100% satisfied would recommend to anyone.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Ice dispensor motor would run but would not dispense ice at the door!
To get the coupler off the motor shaft I took two adjustable wrenches and slit the old coupler where it was cracked.The threads on the motor shaft were stripped closest to the motor.I took two thin washers and put them on the motor shaft so the new coupler would not turn down to where the threads on the motor were sripped.Since the threads on the coupler are left hand they keep the coupler tight as the motor turns the dispenser auger to dispense the ice.I was a bit difficult to unplug the wiring harness but got it after we used a screwdriver to keep the tab bent down until the harness was unplugged.
Ice dispenser freezing up, dispenser door not closing completely.
First off, if you have the stainless steel panel inserts on your refrigerator you'll need to remove those to do this repair. I kept looking for the access holes on the underside of the dispenser panel that you're supposed to insert a screwdriver into to pry it off. It wasn't until I removed the freezer door handle, slid the lower stainless panel insert out, and removed the rail just beneath the dispenser that I could see and access these holes. I also removed the upper stainless panel and rail just above the dispenser to allow enough movement get the dispenser cover off and out. The rest of the repair is pretty straightforward. The old ice door was beaten up and not closing completely, this was letting warm air into the freezer which was melting and re-freezing. This kit fixed the problem.