Dryer would not heat up
Unplugged the dryer from the wall. Removed the front lower cover. Removed the two screws for the bracket that holds down the coils. Unplugged the coils and swapped them out. Reassembled everything in reverse order. Plugged the dryer back in and started it. It's as good as new.
Parts Used:
M Series New Style Coil Kit
  • Bruce from Feeding Hills, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Gas burner would shut off or not ignite
Found symptoms on Part Select website and confirmed that the problem was the coils. It was extremely easy to find and the site saved me hundreds of dollars on a repairman, labor costs and marked up parts. It literally took about 5 minutes to repair. Awesome site!!Thank You
Parts Used:
M Series New Style Coil Kit
  • Stephen from Grand Haven, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
gas dryer heating intermittent
1)Pulled electrical connectors off each of two gas valve coils. 2)Removed two Phillips screws and removed coil retainer bracket. 3)Lifted off two old coils and replaced with two new coils. 4)Replaced coil retainer bracket and plugged back connector on each coil; total coil replacement time is less than two minutes. 5)Confirmed gas valve opens and gas ignites every time over a two day test period. 6)Re-installed door. Wife Happy. We spent under $20 for 'M' series new style coil kit; and the $7 shipping got it here in two days. What a deal! Terry Rahmer 8.24.2012
Parts Used:
M Series New Style Coil Kit
  • terrence from irving, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Gas Dryer not heating.
Unplug the Dryer; remove the lower exterior cover and white plastic drum vent with nut drivers. These two fuses will be setting on top of the function board in front of the gas heating tube.
With a short screwdriver, remove the fuse cover/holder, lift fuse and unplug, replace, re-plug, screw back the cover/holder and you’re done.
Reverse your initial actions...
Parts Used:
M Series New Style Coil Kit
  • Pj from Magnolia Springs, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
the gas would not come on after the igniter lit up.
I replaced the two coils that regulate the gas to turn on and the other to hold open to burn, unplug two connections and remove 2 screws and then replace the coils less then 5 minutes to do this,
Parts Used:
M Series New Style Coil Kit
  • Nickels from West Allis, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
dryer heats up for seconds and stat cold
open the back pannel and use multimeter to check the wirings and everything checks ok. open the bottom front panel of the dryer and turn the dryer on. the igniter works and the flame came out for seconds and dies off. the igniter keep coming on, but it seems that the gas was not coming out. i checked the gas line valve and it was open. i had a good idea it wasn't the wiring or the gas line, it must be the coil-valve,(safety coil), that letting the gas flow. i order the parts, it came sooner, which is good, and it took me less than 10 minutes to install, and i only use a philip screw driver. i thank you for sending me the right part in short period of time.
Parts Used:
M Series New Style Coil Kit
  • donald from anchorage, AK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat.
Checked heating element and it glowed so I replaced the ceramic gas valve regulators. 4 screws to take front off the dryer and 2 screws to replace part. Couldn't have been easier but I wouldn't have been able to do it without watching the video first.
Parts Used:
M Series New Style Coil Kit
  • Henry from Weston, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Dryer would heat for only a minute, then not re-ignite
Remove the two screws holding the door and lift straight up. Remove the two screws on oppostie side. Face can now be removed by pulling straight out at the top, then lifting face up off of tabs at the bottom. The two coils are at the bottom, held in by a retaining bracket. Remove the screws that hold the bracket. Replace the coils by unplugged their wires. That's it!
Parts Used:
M Series New Style Coil Kit
  • Steve from Glendora, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The ignitor would lite, but no gas from the valve, then ignitor would shut off
It was a fairly simple repair to perform with the dryer in place. I simply opened the bottom/front access panel to start, the door removes if you pull up after opening. Then I disconnected the two and three wire connector to the two coils. Next I removed the bracket screws that fasten the coils to the valve assembly. This was a little difficult with the screw closest, because of the small clearance and #1 sized phillips(stubby would work well.) The rear screw I managed to remove by using both a small flathead screwdriver(hex shaped shaft) and an adjustable cresent wrench. At this point, it was a simple matter of installing the new coils and the bracket, and then reconnecting the two plugs. It almost made me want to do laundry.
Parts Used:
M Series New Style Coil Kit
  • Lee from Madisonville, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
dryer cycles but will not heat
removed front cover and turned unit on, igniter would glow red but burner would not start. ordered m series new style coil kit and installed. turned unit on and igniter came on and burner started right away. all thanks to parts select trouble shooting guide.
Parts Used:
M Series New Style Coil Kit
  • daniel from mercedes, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
not heating
two screws on lint screen push up top two screws on front cover. two screws on coils lift coils off put back together. less than 10 minutes. all done
Parts Used:
M Series New Style Coil Kit
  • James from Kingman, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Clothes are not drying
Opened the dryer door - removed two screws on the left and two screws on the right - pulled the front panel forward and lifted it up to remove. The coils were located on the bottom right hand corner of the dryer, I vacuumed he area and then removed the two screws and bracket which hold the coil in place. Lifted the new coils off paying close attention to their orientation. Installed new coils. Align tab on top of coils with bracket. installed bracket and screws. Tested dryer and then replaced front cover. Very easy and rewarding.
Parts Used:
M Series New Style Coil Kit
  • Scott from Blackstone, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Dryer quit heating.
Removed two screws from front panel and lifted front panel away, Turned it to the left so I could keep the door switch connected. The dryer would heat when it was first started, but then the burner would go off and would not come back on. I ran the dryer with the front panel off and could see the igniter glow and light the burner, but after the burner cycled off, the igniter would come back on but the gas would not come back on. I could tell it wasn't the thermostat because the igniter would come on, so I knew it must be the gas valve, and therefore probably the coils. The instructions on the website said that the coils were frequently intermittent, so that seemed like the problem. I tried checking out the coil resistance with an ohmmeter to try to confirm that, but couldn't really tell anything that way. I ordered the replacement coils Tuesday night, selecting the cheapest shipping; they shipped on Wednesday, and were delivered on Thursday! Amazingly fast! Removed two screws from the clip that holds the coils in place, unplugged the old coils, swapped in the new coils, screwed the retaining clip back on. All done. Before I replaced the front panel, I watched to see that it operated correctly. I could see the burner cycle off, then after a bit, the igniter glowed, and then the gas came back on and lit, just like it should. Problem solved. Put the front panel back on, and that's all there was to it. Well, I did vacuum out some of the dust inside the cabinet while I had the cover off. Just out of curiosity, I checked the resistance of the new coils before I installed them to compare with the old ones. Couldn't see much difference.
Parts Used:
M Series New Style Coil Kit
  • John from La Crescenta, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Gas only came on for the first time. Wouldn't 'light' after that.
Followed videos seen on the internet for my dryer's repair. Went exactly as shown.
Parts Used:
M Series New Style Coil Kit
  • Richard from Oakland, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The dryer would light in the beginning of the cycle and not come back on
I opened the 5x5" door in the front of the dryer. Unscrewed the clamp holding the two coils down replaced/reconnected the coils and screwed the clamp back down
Parts Used:
M Series New Style Coil Kit
  • Louis F from West Tisbury, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?