35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Parts Used:
Water Tube Kit
  • Melvin from OPELIKA, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fan quit
I took the old one out and put the new one in. EASY!
Parts Used:
Evaporator Fan Motor Kit
  • donn from Ranier, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice getting stuck, and water flowing over everything
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Parts Used:
Replacement Ice Maker
  • Randal from Wakefield, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Chirping sound coming from the freezer-old gasket on food door causing air leakage r
Removed shelving,ice maker & other air deverters to get at fan motor. Disconnected power, then removed motor by removing screws holding motor assembly in place. Push fan blade on to motor reconnect wiring.
Chirping stopped and ice cream is now rock hard.

Food door gasket was more time consuming than hard. Loosen old gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
Parts Used:
Evaporator Fan Motor Kit Fresh Food Door Gasket
  • JAMES from WAUPACA, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water pump for ice maker would not shut off
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires...) Then I put the new valve in, put the cover back on the refridgerator and was done. total time 15 minutes. My wife says I'm the man.
Parts Used:
Single Outlet Water Valve Kit
  • Lawrence from Clio, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator would freeze up and stop cooling, I would turn off defrost over a 24 hour period by leaving the freezer door open. Then turn it back on and it would cool like crazy for about a week and then it would freeze up agian. This went on for about a month then I knwe the problem was in the defro
The first thing to do was determine what part of the defrost circuit was bad. (it could have been the defrost timer assembly or the defrost heater or a bad wire in the circuit). To do this I took the cover off of the refrigerator temp control to see the timer. Taking a large screw driver I rotated the timer (clockwise) until I heard the compressor cut off. Then I placed a mark on the timer to note its location and waited to see if the mark moved( this indicated the motor was running). After 20 minutes the compressor kicked back on and the timer had rotated, this told me the timer was at least rotating. The next step was to see if there was voltage going to the defrost heater around the freezer evaporation coil. (The heater is what melts the frost of the evaporation (cooling) coils
This requires the removal of all the shelves, ice maker, and all the covers in the freezer section to expose the evaporation coil.
The defrost heater wraps around the outside edges of the evaporation coil. The heater is suppose to come on for 20 minutes every 8 hours to keep the evaporation coil from becoming covered with frost which will prevent the air from circulating into the refrigerator section.
I found where the heater leads plug into the back wall of the freezer and with the power on and in the defrost cycle (turn or index the timer around with the large screw driver until the compressor cuts off again). Carefully read across these two heater leads and check for 120 VAC. Noting there was 120vac across these two leads I then turned the refrigerator off and unplugged the refrigerator from the wall.
Now with the Volt Meter set to the Ohms setting I unplugged the two heater leads with the needle nose pliers and read the ohm value across the two wire leads of the heater element. (I got lucky and found a schematic folded up and stuck just behind the front grill at the bottom of the freezer). The schematic told me the ohm value should have been 22 ohms. However, my value was 0 ohms this told me the heater had an open circuit (it had a broken wire inside the heater element). I located the correct part using the model # on the Part Select website and ordered the defrost heater element for my model refrigerator. I received the part in three days.
Now for the fun part, of removing and installing the new element.
This is not brain surgery but … it is not for the faint at heart either, you must be able to work in tight areas and be agile enough to sit on the floor while reaching the back of the freezer and be patient and deliberate with your moves. (kind of like playing the Milton Bradley game “Operation” as a kid)
Next step is to remove the two top screws holding the evaporation coil to the back of the freezer, then remove the cover to expose the refrigerant lines inside the freezer, remove the two foam side supports holding the coil centered in the back of the freezer and then VERY carefully lift the evaporation coil straight up to un- hook it from the bottom clips which hold the bottom of the coil stationary. Then gently remove the two aluminum side plates from the coil by bending the tabs that hook these plates to the curved refrigerant coils they are hooked around. With the side plates removed then carefully un- hook the 4 clips which hold the heater in place around the evaporation coil. Using a pair of needle nose pliers unplug the heater leads from the back wall contact point (Remember to be sure and unplug refrigerator before doing this) At this point VERY carefully lift up slightly and gently pull the bottom of the coil out (trying to keep the top of the coil at the same elevation and parallel to the back wall pull the bottom out to a point where the heater element can be slid down and out of the evaporation coil as it is basically woven thru the coil assembly to efficiently defrost the coil.
Once the heater is carefully slipped down and out of the evaporation coil, replace the heater element with the new one by feeding the wires bac
Parts Used:
Heater
  • Charles from Dripping Springs, TX
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Parts Used:
Refrigerator Door Switch
  • Michael from East Meadow, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • David from Choctaw, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working after less than six months
After checking all connections I determined the ice maker which had been replaced on 01/2007 stopped making ice. I had serviceman from a local company return and check the ice maker. He rinsed the ice maker under warm water, melting the ice build-up and re-installed the ice maker. I watched him do the re-installation, then waited for two days to see if the ice maker was functioning. Since the ice maker wasn't working, I called the serviceman, who in turn informed me that the replacement ice maker had increased in price from $170.00 to $274.00. That is when I contacted your web site, ordered the replacement ice maker.
I was totally amazed and pleased by the fast,
easy, and efficient way my order was processed and the ice maker was delivered.
I followed the instructions included with the ice maker, and installed the replacement ice maker in about 20 minutes. I can't thank you enough for the great service. I only wish I had checked my computer after the first ice maker broke down and found your web site.
Parts Used:
Replacement Ice Maker
  • Claude from Oakdale, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Parts Used:
Refrigerator Door Switch
  • Antonio from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker slowed down, then stopped producing
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing with two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Parts Used:
Single Outlet Water Valve Kit
  • Paul from Sharpsburg, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working. Thought it might be the timer. Actually teflon coating coming off.
Removed the ice maker. Used a small mirror (wife's make up mirror) to find the screws. Inspected and found most teflon coating missing. Ordered new ice maker and installed. Works perfect.
Parts Used:
Replacement Ice Maker
  • David from NASHUA, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Parts Used:
Water Tube Kit
  • Monica from EDMOND, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
6 of 8 people found this instruction helpful.