WRX735SDHW03 Whirlpool Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
no water when under sink water filter installed
I called the installer of my filter unit and he told me that often, thhe fridge filter is the problem. Like magic it worked
Parts Used:
-
Emi from Arlington, VA
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
11 of 19 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking water onto floor
replaced the poorly designed "duck bill" drain with this P trap. Very simple repair done by accessing through the back of the refrigerator. The video on this website walked me right through the repair. It did however fail to mention that the ice has to be removed from the inside. I had to remove the drawer face and pull outs. Then the ice maker and back panel are removed. I used a heat gun and screwdriver to chip and melt the ice build up. If one had the luxury of having another refrigerator to move food in to you could just unplug the unit until the ice melts.
Parts Used:
-
Mark from ALTO, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed
Parts Used:
-
Daniel from RICHTON, MS
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
10 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken latch on water filter cover.
Reviewed replacement instructions video on your website. Just followed the easy instructions to pop out old cover and pop in new cover. I would not have tried to replace it myself had I not seen your video. Super easy.
Parts Used:
-
Gloria from Laurinburg, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Chaged out Door Light Switch
By sliding athin screwdriver blade down the side of the old switch the expasion prong that hold the switch in place was compressed enough to allow the switch to come out easlily. Plugged in new swithc and snapped in place. Plugged the refrigerator back in and light has worked great sense!
Parts Used:
-
Scott from Kansas City, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
7 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It's a 8 light panel it's on series one goes down light drops to lower. I didn't care but my wife did
Remove first cover remove the light panel and replace it
Install everything back...
Install everything back...
Parts Used:
-
Carlos from PICO RIVERA, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
6 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Freezer worked fine, but upper refrigerator would not cool.
I first replaced the lower (freezer) evaporator thermistor based on recommendation from other feedback, however that did nothing to resolve the problem. I subsequently discovered a diagnostic document hidden under the upper right door hinge, which helped me narrow the problem down to the upper (refrigerator) evaporator fan motor. After replacing the fan motor, my refrigerator is up and running again. The only challenge was accessing and removing the access panel(s) and air column. Once those were removed, replacing the fan motor was simple.
Parts Used:
-
Stephen from Jacksonville, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Nutdriver, Screw drivers
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
RH door closure broke
Removed the door and replaced the broken door closure bushing. I had courteous help and responce from Parts Select people. Excelent turn around time on parts delivery.
Parts Used:
-
Estel from Luling, TX
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
10 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Did not need filter
-
Geraldine from MUNDELEIN, IL
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken black plastic spring mechanism inside freezer rail
Remove rail and removed broken black plastic spring mechanism with new one and then replace rail.
Parts Used:
-
Ronald from WESTERVILLE, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
7 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken light switch in the freezer
We removed the old switch, unplugged it, plugged the new one in and it was easy to do. But when we tried to put the switch back in we had a very hard time doing it. Eventually got it in, but if it had not been for the difficulty we had getting the new switch to snap in to place, it would have taken under 5 minutes.
Parts Used:
-
kathleen from GREEN VALLEY, AZ
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Control noisy when opening and closing removed damper housing
Pop off vent cover remove 2 screws removed cover housing and foam. Removed damper by unclipping tabs on left and right side of control lift up and out. Unplugged power wires reinstalled in reverse order.
Parts Used:
-
Nelson from CATSKILL, NY
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy damper
Easy fix, it's right in the back of the fridge under a cover that just clips in, a piece of foam, and two screws. The hardest part is getting the clips free without breaking them. After replacement it's silent instead of making a grinding noise regularly.
Parts Used:
-
Keith from OLYMPIA, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
A cover over the water filter was broken
The old cover was off and I just slid the replacement part that I got from you'll, it just slid in place and snapped close. Perfect fit. Thanks guys
Parts Used:
-
Jerry from MIDLOTHIAN, VA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch that causes light to turn on when door is open was nroken.
Truth is, this took a couple hours of cursing, but that was due to poor information and no prior experience. I imagine the next one would take 20 minutes. The issues are these: videos tell you to use a putty knife to pry the old switch out. That is harder than it seems because each switch has a plastic spring that pops open to hold the switch on, and you can't access the spring when the switch is installed. So it is important to use the knife on the side of the switch (left or right of spring -- look at the new switch), and back and forth until the switch is worked out. Then it can get worse. The new switch has to plug in electrically before it can be installed mechanically. In my case, with the switch on the fridge wall rather than the top, the outlet for the plug was encased in foam insullation. That gives the appearance that the plug was fixed, immovable, which makes it impossible to plug it in electrically before the switch is in place, and of course once it is in place you can't then plug it in. The problem here was poor instructions. Just scrape out a lot of the foam around the plug and you find that the plug is really not fixed, but attached to reasonably long wires that allow you to plug it in with the switch a couple inches from the wall, and then insert the switch. None of the online instructions tell you this about the wires.
Parts Used:
-
John from WASHINGTON, DC
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!