Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!

-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!

-Set both temp control knots to 5 & put back all the food!

-If no ice build up on the panel after 10 days & then the repair is good!
Parts Used:
Defrost Heater and Bracket Assembly
  • Eddie from Freeport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
52 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser leaked - tubing broke
Ordered parts from another vendor - got wrong parts (1/4 in parts instead of 5/16 in parts). With your parts, I just cut out the bad portion of the tubing, and replaced it using the 2 union connectors. Thanks.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Thomas from Poway, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
48 of 65 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
solenoid opened ice trap door at random
Unplug the refrigerator
Front cover of ice dispenser snaps off. Remove the 4 screws from the ice chute. Unplug the control module that opens the ice chute. Leave hanging while removing the 4 screws that hold the solenoid in place.(one is a ground wire...note location before taking apart). Unplug the two wires to the solenoid.
To install the new solenoid put the plunger in place and at the same time hook on the trip arm of the clapper door of the ice chute. Plug in the two wires to the new solenoid
Replace the 4 screws.
Plug in the Control modules and screw back in place
Plug in the refrigerator. Do a trial test.
Replace the cover
Parts Used:
Dispenser Door Solenoid Kit
  • Betty from Ten Mile, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
40 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Parts Used:
Ice Maker
  • Jeffrey from Bluefield, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
40 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator side of the side by side refrigerator stopped regulating its temperature causing cans and bottles to burst.
I removed the back panel held in place by 5 screws. I located the thermostat and disconnected it from the wire connection to another part. Due to the connection requirement, I had to cut the wires from the original part and splice the connector with wires to the new part. After securing the spliced wires and covering in electrical tape, I replaced the panel and all screws.
Parts Used:
Defrost Thermostat
  • Jonathan from Cary, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
36 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak on the water valve
I had noticed water on the front left of the fridge on the floor.I thought it was the drain in the freezer so i poured hot water with baking soda into the drain but it didn't help..I pulled the fridge out and saw water dripping from the water valve solenoid.I searched the web for parts and found Parts select.com.I found the part quickly and they had pictures from all angles to assure me that it was the exact part which was great.The transaction on line was simple and the part came the next day.I will definitly use this sight again
Parts Used:
Primary Water Inlet Valve
  • JAMES from LEDGEWOOD, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
44 of 65 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Parts Used:
Ice Dispenser Solenoid Service Kit
  • James from Greenville, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
42 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
Parts Used:
Ice Maker
  • Joe from Brentwood, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Parts Used:
Defrost Heater and Bracket Assembly
  • FERNANDO from MIAMI, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
35 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Parts Used:
Ice Maker
  • Steven from Cave Creek, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Older Side By Side GE refrigerator needed filter replaced
Because of the age of the refrigerator, I was unable to find original water filter replacements. I found an adaptor through PartSelect, ordered and received it within 3 days. I was then able to find a replacement filter to work for my appliance. It was easy to install. The Adaptor snapped into the port where the old filter went and the new filter screwed into the adaptor...Water / Ice system is working like new again.

Thanx
Joel
Parts Used:
Water Filter Adapter
  • Joel from Flagstaff, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
42 of 63 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking Water
Unplugged frig. Turned off water supply to pump. Removed black cardboard covering on back of frig with nut driver (6 screws).

Took digital photo of assembly to confirm reassembly position.

Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.

Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.

Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.

NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.
Parts Used:
Primary Water Inlet Valve
  • Paul from Danvers, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
37 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water dispenser in door failed to dispense water
Unplugged refrigerator from electrical outlet for safety and turned off water supply valve. Removed the four metal screws that hold the access cover on the rear of the refrigerator. Then removed single metal screw attaching water valve and bracket assembly. Unplugged wire harness from the water valve and assembly then pressed down on colored o-rings to detach the four plastic water lines from the water valves. Used open end wrench to disconnect main water supply line from the water valve.
Pressed down on colored O-rings to install the four plastic water lines to new water valve and bracket assembly. Wrapped plumbing tape on threads of inlet valve and and used open end wrench to attach main water supply line to new water valve and bracket assembly. Attached wiring harness to new water valve and bracket assembly. Mounted new assembly to refrigerator with single metal screw. Turned on water supply valve and checked for leaks. Plugged in refrigerator to electrical outlet and tested water dispenser. Replaced access cover on rear of refrigerator with four mounting screws.
Parts Used:
Water Valve and Bracket Assembly
  • Robert from El Paso, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
31 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Parts Used:
Ice Maker
  • John from Lodi, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
33 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frige was warm and freezer was freezing up
i turned off the fridge and unpluged it , took out all the shelfs in the freezer and took off the back panel to get to the heater , the heater is only held in with 2 screws and unhook the 2 wires and replace the heater , and then thermostate is on top of the coils , i just cut the 2 color coded wires and replace the theromstate , was easyer then i thought ,
Parts Used:
Defrost Heater and Bracket Assembly Defrost Thermostat
  • kevin from plant city, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
33 of 43 people found this instruction helpful.
Was this instruction helpful to you?