HSS22BDMDWH Hotpoint Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Received the Temp Sensor but no documentation how to replace it
I still have not be able to replace the sensor as I've been unable to locate any info, or figure out where it is located. The water valve was easy to replace and took less than a half hour
After looking further into your website I found all the info, diagrams and instructions to replace the Temp Sensor, which was not too involved, thank you. Now to wait and see if this was the cause and my Refrigerator is up and running again
After looking further into your website I found all the info, diagrams and instructions to replace the Temp Sensor, which was not too involved, thank you. Now to wait and see if this was the cause and my Refrigerator is up and running again
Parts Used:
-
Stephen from Sebring, FL
-
Difficulty Level:Very Difficult
-
Total Repair Time:More than 2 hours
28 of 41 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a water leak (undiscovered) from under my refrig
After de-energized unit (by removing electical plug from outlet),I removed the rear panel at bottom of unit. I then removed the mounting screw to the water valve. I then disconnected the wiring assembly from the old unit. I then removed the water supply lines going to the icemaker and water filter. I then placed the water supply into the replacement water valve. plugged in wiring assembly to new unit and rehung water valve inside refrig. Turned water valve on at water supply to check for leaks, finding none I then replaced back panel on refridge and plugged in electrical cord and returned refrige to normal place in kitchen.
Parts Used:
-
Daniel from Anderson, SC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
22 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaked constantly from water dispenser in door
Had to turn off water and remove back panel and with a few tools the part was off and the new part put on in less that 30 minutes!! Finding parts on your website were easily found.
Parts Used:
-
John from Dexter, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Wrench (Adjustable)
22 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Main circuit board wouldn't allow the compressor to come on
-
Leonard from Keller, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
22 of 26 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was noisy and finally quit. Top of freezer was 50, bottom of freezer was freezing.
First I removed the top shelf, ice drawer and second shelf. Next, I used a 1/4" socket and removed the three screws holding the ice maker lower unit, unpluged and removed from unit. I removed the light cover revealing two screws. I then removed the plastic unit holding the fan. I unpluged all plugs and uncliped the white sensor from the back coils. Once the fan was out, I replaced it with the new one by unbolting the fan bracket and putting the new one in place. I clipped the new sensor in place and replaced all the parts in reverse order. I saved $200 in repair costs thanks to PartSelect.com.
Parts Used:
-
Richard from Pretty Prairie, KS
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Socket set
25 of 35 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Parts Used:
-
John from Windham, NH
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers, Socket set
23 of 29 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Refrigerator both warm, frost buildup on freezer coil cover
De-iced cover and removed two phillips head screws and two 1/4 " nutdriver screws to expose coil, defrost heater and defrost thermostat. Deiced the coil and surrounding area with a heat gun. Removed two screws that hold the defrost heater in place, disconnected the wires to the original heater. The original assy. was a single quartz and the new one was a double quartz. This required rerouting the left wire along with the right one, but was no problem as the wire was plenty long enough. Re-installed the assy. with the two screws. I replaced the defrost termination thermostat, even though it tested good, because I have had experience in that it would be the next to go, and not to in-convenience the owner in unloading the fridge a second time. The only difficult part was fitting into the freezer compartment. As usual, order by 3p.m. and shipping is the same day and is a real joy to use Partselect.com
Parts Used:
-
James from Au Sable Forks, NY
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
20 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wouldn't defrost
Unplugged refrigerator, removed cover, defrosted with heat gun, replaced Defrost Thermostat, and replaced single element with double element Defrost Heater. All went very well with minimal difficulty, and instructions that accompanied parts along with the instructional video on your site, made the repair quite easy. The repair is going on the 4th week now, and no freeze up yet.
Parts Used:
-
Aaron from Walnut Ridge, AR
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
20 of 22 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser won't always dispense water
I followed the instructions found on this website. I removed the control panel by inserting a small Phillips screwdriver in the three holes at its bottom. I used the same screwdriver to pull the dispenser assembly down but could have used a larger one. The microswitch could be seen in the assembly at that point and was easily removed by opening the "fingers" that held it in place. I attempted to pull one of the terminals off without using a pair of needle-nosed pliers and ripped the wires right out of the terminal(I was able to find a replacement at Radio Shack). Low and behold after reinstalling the new part, it did not take care of the problem.
My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
Parts Used:
-
Curtis from Corona, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
27 of 45 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
-
Jania from Novato, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
26 of 42 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor does not run
The first component I suspect is the relay mounted near the compressor. I installed the replacement relay and still nothing. I then removed the control board, inspected it for burnt circuit paths or components. I noticed the c.b. relay for the compressor's lead had burned away the solder and there was no longer a viable connection. Not sure why this happened but my next step is to a) reestablish a solder connection. If this fails then b) replace the control board.
Parts Used:
-
Craig from Soldotna, AK
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
26 of 42 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator wasn't cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires, it was really simple. I conected the new element & defrost themostat (instuctions were included with the parts). I replaced the cover pluged the fridge in everything was woking fine. I placed a themometer in the fridge & have been watching it for 2+ weeks now it is working fine. To anyone who is looking to do this repair, on thier own, I reccomend it. It was very simple & required little to no skill. No reasopn to throw away money to call a repair man.
Parts Used:
-
James from LaGrange, KY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
19 of 23 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Parts Used:
-
D from ZELLWOOD, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
15 of 17 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loss of refrigeration
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...
Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.
With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.
With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.
With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.
Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...
NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.
With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.
With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.
With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.
Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...
NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Parts Used:
-
Heather from Pennington, NJ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
15 of 17 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
-
Sherry from Auburn Hills, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
15 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!