Cracked shelf rails
Removed the cracked rails in the door and snapped the new ones into place.
Parts Used:
Door Shelf Bar
  • Scott from COLORADO SPGS, CO
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Was getting too cold
Was only two screws after that carefully took the part away unplugging the wires at the same time was plugging in to the new part and was done after 5 or 7 min
Parts Used:
Temperature Control
  • Jose A from WEST PALM BCH, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Shelf was cracked on both sides
I first washed old shelf to make sure glass will easily slip out. Installed old glass and replaced.
Parts Used:
Vegetable Drawer Shelf Frame
  • Marcella from SPRINGFIELD, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.

No tools needed, the cap is just held in place with pressure from the wire.
Parts Used:
Light Bulb - 40W
  • Catherine from SEATTLE, WA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fixed shelf was cracked.
I popped out the old plastic shelf and slid in the new one. It was self explanatory and took less than one minute with no tools.
Parts Used:
Door Shelf Bar
  • David from UNION CITY, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Parts Used:
LIGHT SWITCH
  • paypal_shipping_address from Ripon, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the condenser fan motor was intermittently verynoisy. obvious sign of a (possibly imminent) failure
1 unplug the appliance
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
Parts Used:
Condenser Fan Motor Evaporator/Condensor Fan Grommet
  • Herbert from POCONO LAKE, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise in the back of freezer
I must thank yo for sending the fan so fast. If I ever have to deal with any appliance again, you are first on my list.
Parts Used:
Condenser Fans Blade Assembly
  • MaryLou from Levittown, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cracked shelf
took old one out replace new one less then minute
Parts Used:
Door Shelf Bar
  • Joseph from Duryea, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge making LOUD humming sound.
Started removing screws until I got to the fan (it's easy). Then just took out the old fan and put the new one back in the same way. The only challenging part was putting the clamp back on the fan, but I finally got it. The fridge is finally quiet and we can sleep again! PartSelect made it really easy and they were incredibly fast. Thanks!
Parts Used:
Evaporator Fan Motor
  • jack from homestead, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Parts Used:
LIGHT SWITCH
  • Jodi from Benton Harbor, MI
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old fan motor was knocking and not running well
Watched your repair video online. appeared very simple and straight forward. Order the parts in question. They were shipped quickly. Once parts in hand watched video again and then installed new motor and blade in less than ten minutes. Plug power back in and and new part works perfectly. Thanks for helping make it an easy process. J. Smith
Parts Used:
Condenser Fans Blade Assembly Condenser Fan Motor
  • Jacky from Richland, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
Lid Bumper
  • Peter M. from Lincoln Park, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Parts Used:
Evaporator/Condensor Fan Grommet
  • John from PARKVILLE, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan making noise.
Remove ice maker and all of it's accessories in order to remove the panel covering the fan. Don't drop the screws!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Parts Used:
Evaporator Fan Grommet - Red
  • Matthew from Escondido, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!