GS20Y9DV Admiral Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Heater was stuck on
-
Jon from Helena, MT
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker putting black pieces of plastic in the ice
Replaced ice ice maker using
All of the instructions on the website.
Very easy. A couple of the screws I had
To feel for because I couldn't gety big head
In the freezer far enough to see them.
Very simple and only took about 15 minutes.
All of the instructions on the website.
Very easy. A couple of the screws I had
To feel for because I couldn't gety big head
In the freezer far enough to see them.
Very simple and only took about 15 minutes.
Parts Used:
-
Doug from Lewisville, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker was leaking
I read the previous repair story and agree with the author that the screw behind the front piece was difficult to remove and re-install. If I had a magnetized nut driver I think it would have been easier. There were no installation instructions so I relied upon the repair experiences. The other two screws came out easily and I found the harness release easily and the harness was easy to reinstall.
I am not a good handyman but was able to install the new ice maker
I am not a good handyman but was able to install the new ice maker
Parts Used:
-
Jay from Richardson, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice accumulating on evaporator of freezer.
Removed ice maker bin,removed screws on back panel cover. Pulled out panel cover,thawed accumulated ice, unscrewed bracket holding defrost heater set, unplugged busted defroster, plugged in new defroster set,installed it back, installed back panel cover, ice maker and powered it on.More than a week after installation,I don't see any signs of ice accumulation on back panel cover.
Parts Used:
-
rolando from round lake beach, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator compartment warming up
The can drinks in refrigerator were not as cold as usual. I opened the freezer and touched the back panel and noticed there was a frost buildup. Since I have had this problem before, I knew that the defrost heater must be bad. I removed all the shelves and the tracks. The back panel is held in by 8 small sheet metal screws. I removed the screws and pulled the back panel up and out. The refrigerator is in garage, so I put a fan in front of it and the fan melted the ice off the coils. I disconnected the wires and checked the the heaters (both wired together) with an ohm meter. The meter showed the heaters to be open. (bad). Actually only 1 of the 2 heaters were bad, but I replaced both of them since they are wired together as a set.
Parts Used:
-
CHRIS from BAYTOWN, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Black flecks in the ice
I made use of instructions for other users, see 'My ice maker has been shedding.....' and they were very helpful. The one problem not covered - the instructions that came with the new icemaker said to 'remove the bearing and inlet from the old icemaker and install in the new icemaker', but gave no instructions for how to accomplish this.
The old inlet has a square opening in the back and a u-shaped knockout in the side. The new one has a round opening in the side and square knockout in the back)
After several attempts to remove them, I gave up and used the new inlet with the knockout removed. I did not attempt to cover the side opening and it worked fine that way - no leaks.
The old inlet has a square opening in the back and a u-shaped knockout in the side. The new one has a round opening in the side and square knockout in the back)
After several attempts to remove them, I gave up and used the new inlet with the knockout removed. I did not attempt to cover the side opening and it worked fine that way - no leaks.
Parts Used:
-
Jon from Leander, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water into bin (big frozen chunks)
, to remove the inlet tube holder/guide gadget thingee: (1) remove the three Phlipscrews from the motor end of the housing. (2) pull the housing straight off the end. (3) remove two Philips screws in deep holes that hold the ice tray onto the motor housing. (4) this frees the ice tray assembly, which you have to pull out, freeing the rotating blades, from which (5) you slide the sxle out of the middle of the inlet-tube thingee, so (6) you can then remove the inlet gadget from the ice tray.
You then reverse these instructions to reassemble with the correct inlet gadget. The tricky part is the front cover that hides the ice-tray from view. That cover has a couple of ears that have to fit into mating holes in the motor housing before you replace the two deep-hole Philips screws that hold the tighten the ice-tray assembly back onto the motor housing.
So it's too bad they don't see the ice-maker assembly with all the knock-outs inplace, so you can knock out the one you want. Other than that, it would have been no more trouble than other people have reported in working in the tight space inside the freezer compartment.
You then reverse these instructions to reassemble with the correct inlet gadget. The tricky part is the front cover that hides the ice-tray from view. That cover has a couple of ears that have to fit into mating holes in the motor housing before you replace the two deep-hole Philips screws that hold the tighten the ice-tray assembly back onto the motor housing.
So it's too bad they don't see the ice-maker assembly with all the knock-outs inplace, so you can knock out the one you want. Other than that, it would have been no more trouble than other people have reported in working in the tight space inside the freezer compartment.
Parts Used:
-
Roger from Mesa, AZ
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
non-stick coating detioration and water overflow becoming large ice chunks
Ice maker assembly required disconnection of the wire harness at the back of the freezer and the removal of 3 hex nuts. The assembly did not come with a new wire harness nor the rigid wire attached to the hinge that can be raised to stop production of ice. The wire harness was easy to disconnect from the old assembly by pressing in on a tab. The rigid wire attached to the hinge simply required pulling straight out of the hinge-hole (no need to twist, slide, or perform other contortions...it does require significant force to remove, but it does pull straight out). It was simple to attach it to the new ice assembly. Reinstalled the 3 hex nuts and wire harness plug and was good to go....after waiting several hours! I was worried at first because the unit did not immediately fill with water after I plugged the fridge back into the wall socket. However, after the freezer was cold enough, the water did run and I had my first ice dump within about 3 hours of finishing the installation. We have good ice again, and Partselect has excellent pricing and awesome delivery! I received the unit the day after ordering, and I had only paid the basic shipping! Thanks Partselect! Jeff
Parts Used:
-
Jeffrey from Murphy, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stalled out, made excessive noise trying to evacuate completed ice cubes
There are basically three screws that hold the unit in place on the inside of the freezer. Removing them is relatively easy, and the unit is replaced with the same three screws. You do have to use the formed metal wire from your old unit, so don't throw it out! You also have to use the wiring harness from your old unit.
Parts Used:
-
Mike from Clemson, SC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaking into ice tray, frozen glob of ice
installed replacement ice maker kit. 1st removed power. next loosened 2 upper phillips screws. then removed lower phillips screw and lifted and removed old ice maker. released wiring connector and pulled entire unit out of freezer. then i reversed the procedure to install the old unit. check youtube for instructional videos.
Parts Used:
-
james from newfield, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost heater burn out
Frist pulled everything out of freezer put in refridge then took out ice maker box then removed ice maker motor removed back panel took hair drier defrosted the coil then removed bracket screws that hold heaters in place removed bad heater, the hardest part of the job was getting the wirers back around the coils when done just reversed the process.I have a side by side so there was not a whole lot of room to work with. I only weigh 160 lbs it was a tight fit for me. But all in all it went well.
Thanks
Thanks
Parts Used:
-
Jerry from Cleveland, NC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice from icemaker taste metallic; new ice maker directly from box
I did not do the repair yet, there is no schematic on how to route the hose; also no description of how to do the routing/connections.
Parts Used:
-
Samuel from ALEXANDRIA, VA
-
Difficulty Level:Difficult
-
Total Repair Time:More than 2 hours
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Parts Used:
-
Cami from Carmel, IN
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Parts Used:
-
John from Greensboro, NC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
difficulty unplugging the power pigtail
-
William from Las Cruces, NM
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!