Refrigerator would not cool, while the freezer kept food frozen and the ice maker worked fine. Also, noticed frost build up at the rear of the freezer compartment
First, turned off the circuit breaker. Then: 1. Removed all food, , wire sliding baskets, and the ice bin.
2. Removed ice maker by removing the electrical connector from the socket in the rear panel, removed the single bottom screw with a 1/4” nut driver, loosened the 2 top screws with a 1/4” nut driver, and lifting the unit up and off the 2 loosened screws.
3. Removed the freezer door by loosening the 4 screws( 2 on each side) with a 1/4” nut driver and then lifting the door face off the loosened screws.
4. The next task is to remove the panel at the rear of the freezer compartment: use a flat blade screw driver to compress the side clips that hold the ice maker electrical socket, pushing it into the space behind the rear panel, then removing the rear plastic cover in the center of the rear panel, and finally removing the thermistor cover on the right rear upper corner of the rear panel( separate the thermistor from this piece, threading it through the slot in the top of the plastic cover.
Now, the rear panel can be removed by removing the 4 1/4”” hex head screws with the nut driver and gently easing the panel from its position.
5. Now comes the hard part: the defrost thermostat and most of the surrounding “plumbing” was encased in ice. I used a hair dryer to melt the ice, which created an overflow of water drawing into the collection pan; get ready to mop up this water.
6. With ALL the ice melted( this took over an hour), I simply cut the 2 wires, stripped the feed ends, removed the defective unit, clipped the new thermostat to the copper tube where the old unit was clipped, cut excess wire/stripped the new wires and used 2 orange wire nuts to connect each wire.
Now all the parts and pieces can be reinstalled in the reverse order
Parts Used:
Refrigerator Defrost Thermostat
  • Carl from EAST LYME, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not defrost, refrigerator was warm, no airflow into fridge
Info on your site allowed me to determine the most likely cause of the problem, defrost thermostat, and that fixed it. Good installation instructions on the site too. Part was super easy to install. Hardest part was removing the snap-in/screwed-in plastic parts that held the sliding baskets and back panel in place. Didn't break any.....Thank You!
Parts Used:
Refrigerator Defrost Thermostat
  • SCOTT from ELECTRIC CITY, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My old icemaker lost some of the nonstick surface and the ice didn't want to come out
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!
Parts Used:
Replacement Ice Maker
  • Thomas from Ruth, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker would not fill with water.
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.
Parts Used:
Replacement Ice Maker
  • Linford from Cedarville, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator compartment kept getting warm.
The vents at the back of the freezer were constantly getting packed with ice. A repairman failed to spot the problem. I used Partselect's web site to do my own analysis and determined that it was the defrost thermostat.
I followed the web site's instructions, which were exceptionally good. Behind the rear wall of the freezer was a lot of ice on the cooling fins and heavily encrusted over the old thermostat. (It was not really difficult, but I am in my 70s and no longer do things like this on my own.)
After replacing the part, I checked the ohms of the old part and found it to be faulty. Since then, the refrigerator has been working great. I wish I had started here. The repairman I had hired replaced the "control board" at significant expense. I doubt very much that anything was wrong with the old control board.
Many thanks to Partselect for an exceptionally helpful web site.
Parts Used:
Refrigerator Defrost Thermostat
  • Richard from SAN FRANCISCO, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
Parts Used:
Refrigerator Ice Maker Fill Tube
  • Michael from TAKOMA PARK, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
COILS WAS ICING ON REFRIGRATOR SOLID ICED FOUND ENTIRE COILS
CHECK DEFROST THERMOSTAT WITH VOLT OHM METER AND FOUND THERMOSTAT BAD ALSO OHMED OUT HEATER AND HEATER CHECKED OK INSTALLED HEAT SRINK CONNECTORS ON NEW DEFROST THERMOSTAT PUT SYSTEM BACK INTO O
PRATION ALSO CHANGED WATER FILTER ON REFERGRATOR
SYSTEM WORKING OK AND NO ICING OF COILS THANKS WADE BOYLES
Parts Used:
Refrigerator Defrost Thermostat
  • WADE from PILOT MTN, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker stopped making ice.
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.
Parts Used:
Replacement Ice Maker
  • Thomas from Cupertino, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Appliance has Freezer on bottom and Someone dropped Item on handle a broke it
2 Screws on and off
Parts Used:
Freezer Door Handle
  • David from Valley Grande, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
needed a replacement crisper pan drawer for fridge
The part came the next day, very quick. The wrong size ended up in box we recieved. The part # we ordered was correct, just a mix up in the packaging process. I called and the customer service dept. had a new correct crisper pan delivered to my door two days later. Even with the mix up it was very fast and a good price compared to other sites. I would order again in the future.
Parts Used:
Refrigerator Crisper Pan
  • Angela from Oconomowoc, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken freezer Handle
I just took the old one off and put the new one on..
Parts Used:
Freezer Door Handle
  • lisa from sunrise, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Control noisy when opening and closing removed damper housing
Pop off vent cover remove 2 screws removed cover housing and foam. Removed damper by unclipping tabs on left and right side of control lift up and out. Unplugged power wires reinstalled in reverse order.
Parts Used:
Refrigerator Damper Control Assembly
  • Nelson from CATSKILL, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.

But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.

Maytag should recall that Rocker Switch and build with better materials.
Parts Used:
Door Switch
  • Sung-Su from BISMARCK, ND
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thought motor was bad freezer cold fridge hot
Ordered new fan motor
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Parts Used:
Freezer Evaporator Fan Motor 115v 60hz
  • Wayne from PENNINGTON, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?