lights blown out
replaced lights in refrigirator and freezer
Parts Used:
Light Bulb - 40W
  • Gerald from WINTERVILLE, GA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
6 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker stopped making ice.
Did the repair just as the instruction said, once I read it. The part I didn't read was that if the plug was under the ice maker, you had to take the wire out of the clip on the side. So, had to dismount ice maker, unclip wire, remount maker, plug it in. Still under 30 minutes. Thank you.
Parts Used:
Ice Maker
  • Hugh from LADSON, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacing the Hinge Cam Riser (GE Part # WR02X10140) - it was brooken
I have just followed the instructions on the youtube video: It is really easy. I did. Thank you
Parts Used:
Hinge Cam Riser
  • Itamar from SARASOTA, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lower door hinge worn
I replaced both lower hinges without removing the doors. First a couple of observations. The hinge kit consists of two parts; the lower part (bolted to the case) consists of an “L” bracket with a plastic cam, and the upper plastic cam (attached to the door). For some reason the upper cam is available as a separate part . If both cams are plastic both are worn out. Don’t bother ordering the individual cam. If one hinge is worn out the other probably isn’t far behind. Consider replacing both at the same time. Examine the door check. It is an inverted “T” shaped bracket bolted to the door that also holds the door cam. The crossbar of the T are metal tabs that check the door swing. Way too fragile IMO. On mine the refrigerator side was cracked and broke off when I removed it. Since the stops are the same right and left. I just swapped them when I replaced the hinges. Saved $22. Replacing the hinges without removing the doors. {Warning if this technique goes wrong you will be stuck with a loaded door you can’t open.} Remove the vent grill. Stack three 2x4’s along the bottom of both doors ( 26” is about right ). Shim the door(s) up to compensate for the cam wear. About 1/8”) Use a 5/16 socket to remove the hinge from the case. Pay attention to placement of the shims and spacers. Then remove the door cam and stop bracket. Install the new door cam. Leave the screws a little loose. Replace the lower hinge and tighten the screws. Do both sides. Then carefully remove the shims and 2x4’s. Finish tightening the door hinge screws. Check the door swing. I used this technique twice. One to replace the refrigerator side hinge, then again to replace the freezer side hinge and swap the door checks. There were no problems and I saved the hassle of unloading and removing the doors.
Parts Used:
Bottom Hinge Assembly
  • Max from TUCSON, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve cracked
Pulled out the fridge - unpluged. Water supply was already closed.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Parts Used:
Dual Inlet Water Valve
  • Terry from Grand Forks, ND
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water won't stop running in Ice Maker
Basically I looked online for some research thru google and found this great site.. A few other folks had the same problem as I had with mine and I figured that I would start with replacing the double outlet water valve.. So I ordered it from this site and in two days wow that's fast shipping.. This repair took less than 15 minutes to complete and talk about a big savings $ 45.00 for this repair job.... I'm really happy now.... It's pretty easy though.. simply unplug frig first... then remove screw holding the valve.. remove clips and have a bowl near by when remoing the two hoses... replace valve.. its all colored coded just match the colors and then the two hoses they are different sizes one for each hole... reclip the clips and then replace the screw and finally plug the frig back in.. and then turn on the water to check for leaks.. if no leaks you are done...
Parts Used:
Dual Inlet Water Valve
  • Tony from Charlotte, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge evaporator coils frozen
Determined that the defrost heater was bad (didn't test the thermostat or sensor) and attempted to replace it first.

Got the part in one day (super fast shipping).

1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Parts Used:
Defrost Heater Harness Kit
  • Michael from Purcellville, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster unit went out
First let me remind you my husband is disabled so it was up to me to do the repair. I'm 70 yrs old. I first removed everything from freezer and then removed the back cover removimg 4 screws,then i removed the old defrost unit which held 2 screws replaced with the new one then i had to put cover back in place..then put everything back in freezer and so far its working...Only time will tell.But the part was so reasonable that if if i have to i will get another..but not for a while i'm hoping,
Parts Used:
Defrost Heater Harness Kit
  • Pap's Sport Shop from Webster Springs, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leak from the Water Valve.
I received my parts in 2 days, that is fast. It took me less than 15 minutes to install the unit. Now I've got ice and water from my refrigerator. Instead of taking expensive warranties, I would rather order parts from your company and do it myself on all my appliances.
Parts Used:
Dual Inlet Water Valve
  • Tony from Conover, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench set
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Parts Used:
Ice Maker
  • Robert from Wyckoff, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
Parts Used:
Dispenser Door Assembly or Flapper
  • Roger from Colleyville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The icemaker quit making ice and the water started forming on the bottom of the ice bucket.
First I removed the electrical plug from the back of the freezer that plugs into the icemaker. I then removed the two hex head screws that hold the icemaker to the wall of the freezer and removed the icemaker. I removed the plastic cover, which incidentally protects the gears, by prying it off with a srewdriver. I removed three small nuts(7mm) which holds the internal cam in place. I removed the cam by pulling it off the shaft. Once I got the part from you folks I reversed the procedure that I just mentioned, and put the icemaker back together. It works great. The part with shipping was around $16.00. A new icemaker was roughly $159.00. If I would have called a technician it would have cost around $300.00 to repair.
Parts Used:
Ice Maker
  • John from Anaheim, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.

Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Parts Used:
Defrost Heater Harness Kit
  • Allen from Schenectady, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ran All The Time Did Not Freeze.
Removed cover in freezer over evaporator,unbolted element ,plugged ,and replaced, very simple. Should be first thing checked when theres a problem.
Parts Used:
Defrost Heater Harness Kit
  • GARY from SPRAGGS, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer freezing and fresh food compartment not cooling
i unplugged the fridge, first i removed the racks, then unhooked the grounding clip. the i tool off two 1/4 nut screws holding the backplate. then i used my wifes hair dryer to thaw out the ice. after it thawed out i unscrewed the element bracket which is secured by two philips screw. after taking the screws off, its just unplug one end at a time and plug it to the new one to avoid confusion. then reverse install to put back together.
Parts Used:
Defrost Heater Harness Kit
  • ronald from palmyra, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!