Freezer is cold, Refridgerator is not as cold as it should be
Having seen this problem before in other equipment so I had an idea where to look. Problem: the automatic defrost function was not operating. Looking through openings in the back panel of the freezer compartment, you could see the evaporator coils and fins were a solid chuck of ice. There are three logical components to check. Heater element, thermostat (located just above the evaporator) and a relay on the control board (located in the fridge control panel). Checked the heater with an ohm meter -- OK. The thermostat closes the circuit at around 20 degrees and opens at around 32 degrees. Pulled out the thermostat, wiring, fan unit. Everything unplugs, unscrews, and unclips, don't cut wires. Put the whole assembly in a friends freezer for an hour or so to see if the thermostat closes -- OK. Problem had to be with the control board. Replaced control board, reprogrammed it per included instruction. Everything is working again.
Parts Used:
Refrigerator Electronic Control Board
  • Russell from Hardinsburg, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
382 of 470 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defroster mode was not working causing freezer to ice up and refrigerator to be warm. Also fan was running continuely
The hard part for me was figuring out which part was causing the problem. I read what others had done and followed their test methods. I checked the defroster heater for continuity and the defroster thermostat to make sure it was closing. the defroster termostat has to be cold to check it. You will need to check it while it is in ice or take it out and put it in another freezer for 30 mins and then check it for continuity. Those items checked out ok so it had to be the control board. The control board is a 5 min job to replace but making sure that is your problem is the hard part. I think the control board was bad due to a power surge we had when the power went out and came back on. It might be a good idea to put a surge protector on your home to protect your fridge and all your other electronic stuff. Our refrigerator is now working like new again. Thank you for all your help, Jim
Parts Used:
Refrigerator Electronic Control Board
  • James from Welches, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
187 of 226 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Top unit was not getting cold
First thing to do is take two screws off where the door closes.I removed the light sheild off by pushing it to back of refrig.The most hardest part is removing the complete panel,I took a small flat blade scraper to ply down to get small access than you need to put alot of pressure to start getting the panel to start coming off there are alot of pegs to free,the back panel has two hinges that slide towards the front.Once the panel drops remove the connectors and take entire unit out,very easy to replace the control board at this point.Installation is easy slide the two hinges on back in place and put pressure on unit to snap entire unit in place.Program unit with paperwork that came with part very easy to do.Frig is working great now.Just a note the paperwork on refrig is located in the front right corner the mf hids it ,this information will allow you to check all problems with refrig using the key pads for freezer/refrig.Good luck.
Parts Used:
Refrigerator Electronic Control Board
  • Gregory from Lexington, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
149 of 168 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Parts Used:
Refrigerator Water Fill Cup & Bearing
  • David from Chester, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
108 of 138 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not close
After emptying the refrig. door, I unscrewed the plate on the top of the refrigerator that covered the door bolts. Then off with the three bolts. I removed the door by lifting it up a few inches. The two parts of the door cam were easily removed and replaced with the new part. BEFORE REPLACING the door spread vasoline on both cam parts.
(Not after as I did. The second time you do any of these repairs go SO much better :o)
After putting the door back on, adjust the tension of the screws holding the door in place if needed to align the door on the cams so that it shuts completely. Failure to do this will require taking the top off the door again. (see comment above on "... second time...")
If all is properly aligned, the door should swing completely shut.
Even with the mistakes that required removing the door to lubricate the cams, and removing it AGAIN to readjust the screws on the top to properly align the door on the cams, this was a twenty minute job. My wife and I were still speaking to one another at the end of it- a sure sign of an easy repair.
Parts Used:
Door Closure Cam Kit
  • Russ from Asheville, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
79 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor did not shut off evaporator freeze up
replaced control board
Parts Used:
Refrigerator Electronic Control Board
  • Dave from Southampton, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
90 of 156 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leak at fill tube
Removed two screws that held cover plate. remove cover plate. Remove water hose, and clamp, by compressing clamp with pliers. Remove fill tube by pulling HARD, from back.

Replace fill tube, check to be sure that it entered ice maker properly. Replace hose and clamp.
Replace cover and screws.
Parts Used:
Refrigerator Speed Clamp Clip Refrigerator Plastic Tube Insert Refrigerator Ice Maker Fill Tube
  • Richard from Yarmouth, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
59 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not turn allowing the ice to come out the dispenser. The ice bucket was also cracked from kids (ok and parents) getting frustrated and shaking the ice bucket!
Piece of cake!

Removed the old ice bucket which was cracked and ice would not dispense. The Helix Cap also looked worn which is why I ordered both parts. (Probably if not for the shaking of the ice bucket the Helix cap would have been the only part required. We ended up cracking the ice bucket) Removed the four hex screws from the auger system on the old ice bucket with a socket wrench. Removed the old Helix end cap from the auger system and replaced with the new. Literally just slips on the auger. Reinstalled auger system back onto the new ice bucket. Total time not even five minutes.

Working great! Probably saved $ 75.00 - $ 100.00 on a service call. Half of a wrench on skill level needed (One=Low skill level/ Five=High skill level)

Great response & delivery from Parts Select!
Definitely recommend highly.

Todd
Lancaster-PA
Parts Used:
Ice Bucket Ice Maker Helix End Cap
  • Todd from Lancaster, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
50 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
while closing the door, the light switch fouled, resulting in the switch breaking
I used a flat screwdriver and released the lock tab on the bottom of the light switch, and pried the switch out, being careful to not damage the plastic around the mounting place of the switch, unplugged wiring from old switch, plugged in the new one and pushed the new switch into place. Job finished light switch now working.
Parts Used:
Door Switch
  • Kevin from Beckley, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
64 of 113 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Dispenser had jammed up and become inoperative
The parts discription was a bit vague and I wasn't sure exactly what I was ordering, but I received everything I needed and it works fine. The combination screw conveyor/ice crusher came in one piece. The ice cube bin is a plastic assembly that snaps apart. I used a wide blade screw driver carefully to facilitate assembly/disassembly. Once you have it apart the old converyor slips out and the new one slides in. Do not remove the two screws that hold the new assembly together. You need a phillips scredriver to take out two of the screws from the old assembly and put in the new one. That is, there are four screws and you need to trasfer two of them. Everything now works fine.
Parts Used:
Ice Maker Auger and Crusher Blade Assembly
  • James from Robinson, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
40 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door switch module wore out
Pull out old module...
Remove 2 wires...
Tape to inside wall [don't want them to fall down into side panel]..

Order new switch..

Fed Ex pkg came on 2nd day..

Install wires on switch...
Press into opening...
Check door light on..[OK]
.. Done
Parts Used:
Refrigerator Switch
  • Fred from Oceanport, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
40 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:

When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.

LG
Parts Used:
Refrigerator Water Tube Connector/Union 5/16 To 5/16
  • Leo from Salem, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
46 of 80 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
Parts Used:
Refrigerator Water Fill Cup & Bearing
  • Jason from Austin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
33 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Latch was broken on the filter cover and would not hold the filter in place.
Ordered a new filter cover, received in 2 days and installed it in about 5 minutes. Worked perfectly.
Parts Used:
Refrigerator Water Filter Cover
  • Ken from St. Geogre Island, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
34 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door cam worn out
remove top plastic cover / phillips screw driver
remove top door bracket / 5/15" socket
lift off door
remove pieces of old cam / phillips screw driver
replace cam/ phillips screw driver
replace door
replace top bracket / 5/16" socket
check alignment
Parts Used:
Door Closure Cam Kit
  • william from avon, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
27 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!