Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Icemaker would not stop putting out water, then would not make ice
First, I unplugged the power to the entire fridge, and then removed the ice tray and ice door. Next, I unplugged the flat plug in the very back left behind the icemaker. Then I removed the 1/4" hex head sheet metal screws (2) and the phillips head screw (1) that hold the icemaker to the left side of the freezer wall. New icemaker came with a different style trip arm, so I used it. Plugged new icemaker in before reattaching it with the same (3) screws. Replaced ice tray and door, plugged in fridge, and waited....Dumped its first batch of ice maybe a couple of hours later. Not much trouble-shooting is needed when the entire icemaker is as easy and relatively inexpensive to replace as this. Twenty minutes, max.
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
The initial problem was that the ice maker was not working. I had the unit repaired at a local store and they assured me that it worked fine in their workshop. I believed that the valve was the next logical part to replace. The installation was very easy. I unplug the refrigerator and turned off the water. Removed two, easily reached, screws and pulled the unit out. Disconnected the wire harness (you may want to mark the top of the wire harness before removing for immedite alignment on reassembly) and tubing. Notice a spot in the tubing that had been kinked, so cut that out. Reassemble and turned everything back on. Installation went perfectly. Unfortunately, I still do not have ice and will be doing some additional trouble shooting to determine the next course of action. I may be in touch.
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
The evap motor failed (no air movement inside of refrierater
Removed screws from cover tested for power to motor found power was on to motor but motor did not work. I went to your web site was able to locate part in about 5 minutes . Even with over night shipping the part came to about $50,00, far cheaper tha a service call would have been.
Removed the drawers and shelf unit above the shelves. Installed the new rail and put the shelf unit and drawers back in. Less than 5 minute repair. Very fast delivery of part and reasonable pricing.
Remove the light cover. Use a flat head screw driver to push in the tabs on the back of the program mount and pull down to expose the computer board. The Thermistor is clipped on under the vent holes on the right side. Cut both wires to remove the old thermistor strip a 1/4 inch off the remaning wires and the new thermistor wires twist both ends together crimp on the wire caps snap in the new thermistor reinstall the program board until the retainer clips snap into place, slide the light cover back on.
Unsnap damper louver cover using only your fingernails at bottom. Remove two phillips screws from damper cover. Remove styrofoam molded insulation. Squeeze electrical connector to release latch; unplug connector. Release latches on both sides of damper control while gently pulling on damper control unit to remove it. Install new unit by doing above steps in reverse. Damper door may move when electrics connected; keep fingers clear. Amana would not honor our extended warranty that we paid $65 for, saying that noises are not covered. Im glad that Partselect supplied the part quick and and a great price. The frig is quiet for the first time in 2 years!
Remove cover inside frig at rearwall top with screw driver. Remove phillips screws holding unit in place. Unclip connectors ,and replace in reverse order.
Ice Maker would seem like it was the valve was leaking and Ice would build up at the rear of tray. After listening to it cycle, (drop ice and fill) valve would open up again about 20 minutes later. Over flowed and iceberg would form at rear. Replaced icemaker unit and works fine now.
Inside the food section above the top shelf behind the light in the back, remove the lid from the cover in lifting from the lower edge no tools necessary here. Remove two screws with Phillips screw driver remove entire housing inclusive Styrofoam insert. Unplug damper Control Unit. Remove two screws and remove damper control unit and replace in reverse order. Finally that refrigerator is quiet, I should have done this long time ago. Unbelievable this is the second part I have to replace on this expensive refrigerator.
Freezer would get cold at bottom and some of the refrigerator. Took of freezer back panel and located freezer fan. Took a meter and saw power was getting to it, but not working. Removed fan and replaced with new on, working like a charm. Cold air was not circulating enough throughout the unit because fan was not working. It was not the thermostat or adapter control.
1. shutoff water 2. removed 3 screws holding old ice maker. A small nut or screw driver is needed to get into a somewhat tight area 3. detached electrical connector 4. cut indicated area for water inlet to lie in 4. attached new electrical connector (no splicing needed) 5. attached new ice maker with 3 screws 6. put on water