No water to icemaker
The replacement valve was identical to the old one, so I didn't have to use any of the adapter parts sent with the new valve. This made the installation rather simple. After removing the back cover on the lower part of the refrigerator, I turned off the water and electrical supplies, and removed the water supply line to the valve. Then I removed the two screws securing the valve to the refrigerator. Next, I removed the two electrical connections from the valve, and unscrewed the plastic nuts holding the tubing to the valve. I didn't have to use a wrench to do this as they were hand tight, so when I attached the tubing to the new valve I tightened the nuts hand tight. This seemed to be sufficient and avoided the possibility of stripping the nuts. After checking for leaks, I attached the electrical connections and secured the new valve to the refrigerator. Then I attached the water supply line, but before replacing the back cover, I turned on the refrigerator, and let it cycle through it's first load of ice.
Parts Used:
Dual Outlet Valve Kit
  • Walter from Willis, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Dispenser flap would not close-delay mechanism quit working
The hardest part of this job was removing the front cover over the water and ice dispensing unit.

Step 1: remove front cover by inserting flat head screwdriver into one of small slots on the bottom side of the cover. Push up firmly, but not too hard (don't beak the plastic cover). As you are pushing up, slightly pry the bottom edge away from refrigerator door. Then, do the same for the other side.
Step 2: Now with both edges slghtly pried away for door, you will now need to use your hands and apply an upward pressure on the cover. (Understand that there are three tabs on the top side of the cover that must come about 1/4" out of slots on the top side of the door.) Try wiggling the cover, while applying upward pressure. You may find the door handle restricting one of the tabs, but you can slide the cover to the side to get it out.
Step 3: with the cover removed, now you can use the nut driver to remove the one (1) screw that holds the mechanism in place. Be sure to see how it fits over the dispensing lever.

Step 4: Install the new delay mechanism by inserting the prong over the dispensing lever and seat into place. Insert screw and tighten.
Step 5: ensure that you installed the device properly by actuating the ice dispenser. If everything is OK, proceed to next step. If not, make sure you installed it correctly.
Step 6: Reinstall front cover by insering the three upper tabs into slots at the top of the dispensing area. Apply downward pressure with your hands, then push the bottom side of the cover in. You should hear them snap into place.
Step 7: Dispense ice into a glass, add water, and enjoy your finsihed project
Parts Used:
Refrigerator Ice Door Mechanism
  • Alex from Columbiana, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken ice dispenser arm
First of all it's nice to have an exploded view of the ice/water dispenser.
First remove the trim around the ice'water dispenser by carfully prying the bottom out and popping the trim up to release the top.
Remove the 2 screws that hold the light switch and light, move out and to the right, do not disconnect.
Remove the 2 hex screws that hold the old arm in place. This will allow the arm to drop down so you can remove the arms' ice guide.
The arm has a spring for tension on the right side. Remove it and retain.
Above the water dispenser is a screw that holds the ice door closer spring, remove this screw and slide out the spring loaded closer
Loosen the right screw that holds the water dispenser, it is spring loaded.
You should now have room to remove the old ice dispenser arm.
Slide the new arm up into place behind the ice dispenser door
install the spring tensioner to the right side mount screw at the same time align it with the left side of the water dispenser arm. The ice dispenser arm and the water dispenser arm share this mount so both arms have to be in place in order for the arms to work properly.
Install the left mount and screw of the ice dispenser arm
Install the ice dispenser arm's ice guide using the screw removed earlier.
Next reinstall the Ice door tensioner spring and screw making sure the metal arm of the ice door is engaged in the slot of the tensioner.
Finally reinstall the screws to the light swithch and light bar and snap the trim back into place.
Parts Used:
ARM-DISPSR
  • Wayne from Wheat Ridge, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cover Pan Crisper(bottom glass shelf and frame) were broken
New part slipped right into the studs and fit perfectly
Parts Used:
Crisper Cover with Glass
  • anthony from ormond beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Door Leaking
Remove the unit cover by unsnapping from the bottom. Remove the face plate on the switches. The ice door simply snaps off the closing mechanism. The problem I have is that the original door included a heat trace element (keeps the back of the door warm to limit condensation). The new part was simply a new seal. I clipped the leads to the het trace (turn off the fridge before you do that) and put in the new door. When the heat ids on in the house there is no problem with condensation but on warmer days its pretty bad. I cannot find a replacement part with the heating element and have contacted Whirpool. THey haven't responded as of yet.
Parts Used:
Refrigerator Ice Dispenser Door Chute
  • Steve from Metairie, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator No Longer Cooling Properly
Approximately:

1. Unplugged refrigerator.
2. Emptied Freezer.
3. Removed Ice Maker.
4. Waited a few hours for ice to melt around back panel & nuts.
5. Removed back panel and the cover over fan and fan motor.
6. Waited many more hours for ice to thaw over fins, wiring, etc.
7. Easily replaced the bi-mental defrost thermostat.
8. Replaced panel, fan cover, ice maker.
9. Plugged in refrigerator and waited a bit.

This worked! Yahoo.

p.s. I am a 65+ year old mechanically minded woman. :-)
Parts Used:
Refrigerator Bimetal Defrost Thermostat
  • Elizabeth from DELRAY BEACH, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken gooseneck on fill tube
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.

Shut off water supply line, and turn off ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.

Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Parts Used:
Ice Maker Water Fill Tube Kit
  • Thomas from Brunswick, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Crisper Pan Side Reales Had Cracked
I just slid the new pan in , partselect has the correct part all the time , I repalced my ice maker once and it took 15 min no problem
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • LEVY from HOUSTON, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer/refrigerator no air flow
Using a 1/4" nut driver and a philips screwdriver I removed all the screws in the shelf brackets and coil cover and removed coil cover. Removed fan blade and then faulty motor (held in with clips) Installed new motor-two wires (power) and ground (green) pushed fan blade back on and tested, then reinstalled all panels and shelf brackets.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Jim from Au Sable Forks, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would not kick on automatically
I removed the two screws that were readily in view. I then figured out the there was a faceplate which I was able to pry off after removing the temp control knobs. The temp control unit was easily accessible and was held by two screws which I removed with the nut driver. The only difficult part was replacing the plastic tubing which covered the sending unit.
Parts Used:
Refrigerator Thermostat Assembly
  • Robert from Brooklyn Center, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken tray
Remove old tray, replace with new tray.

Simple & easy.

Best part is I ordered on Monday & received on Tuesday!
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Brian from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not dispence ice
Removed screws from front of ice container,replaced drum.
The hardest part was assembly of ice crusher,lucky the arms were lettered as to how they went back together.
Parts Used:
Ice Auger Kit
  • Mike from Chickasha, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
14 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Severed/Rusted Support Shelf Stud
Easy as cutting through warm butter. Just grabbed the base of the broken stem flush with the wall of the fridge using the wide-angle setting of a normal pliers, and twisted it out. Left over was a hole to insert the replacement stem. Inserted stem, twisted clockwise into place, and done. Much better design than other units I've worked on becvause the replacement part has stout-gauge wires that, when new stem is twisted into place, "locks" it in so you don't need to reinforce it, acting somewhat like an anchor screw on the wall for hanging a picture. Thanks for the perfect part!! Service and delivery are excellent.
Parts Used:
Shelf Support Stud - White
  • Chris from Pensacola, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
part of a freezer support bracket was missing
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Parts Used:
Shelf Stud
  • peter from saint augustine, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!