Joshua
January 7, 2020
Wont pick up water out of tray or cleaner i believe pump is bad?
For model number ZDIS15CSSJ
Hello Joshua, thank you for your question. Yes, If the water isn't being circulated through the unit the pump should be tested/replaced. I hope this helps.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Dorothy Mcphetridge
August 1, 2017
Is there refurbished pumps or cheaper pumps compatible to this one
For model number ZDIS15CSSL
Hello Dorothy, that is a great question. We do not deal with aftermarket or any other part unless it is directly from the manufacturer, we only deal in OEM parts. Hope this helps!
Was this helpful?
Thank you for voting!
Stacy
September 20, 2017
Where would i find installation instructions for the circulation pump. Part# wr57x10028?
For model number zdis15cbbk
Hi Stacy,
Thank you for your inquiry. Before beginning any repair, unplug the appliance from the electrical outlet or shut-off the circuit breaker. Unscrew the drain cap from the bottom of the reservoir and let the water drain out and remove the screw from the circulation pump shield. The drain pump is attached to the bottom of the reservoir. Disconnect the drain pump wire harness from the connection plug above the circulation pump. Remove the 2 thumbscrews from the reservoir and pull the reservoir out of the ice maker. Pull out the circulation pump shield and set it aside. Remove the circulation pump outlet tube then remove the screws from the pump mounting bracket and pull the bracket down to access the wire harness connections for the pump. Disconnect the circulation pump wire harness and the sensor wire harness from the connection plugs. Pull the pump and bracket out of the ice maker. I hope this helps. Thank you and have a great day!
Was this helpful?
Thank you for voting!
Phil
April 2, 2019
Is there a way to test the pump? I believe it is the pump that is since the water is not being circulated up to the evaporator plate but i want to make sure before i purchase the part.
For model number ZDI15BWW
Hello Phil,Thank you for contacting us. I suggest removing the pump and testing the terminals with a multi meter and check for continuity. Thank you for your inquiry, good luck with this repair!