Missing regulator when floor model gas cooktop was purchased
1. Apply gas pipe joint sealer to treaded nipple on bottom of cooktop; 2. Install regulator on nipple with regulator direction arrow pointing to top of cooktop; 3. Tighten but do not overtighten as it may crack the aluminum body regulator; 4. Make sure the face of the regulator with the green painted surface faces the outside of the cabinet; 5. Get a new gas flex hose to connect to gas pipe (got mine at Lowe's - 2 feet long with all the right fittings for about $15). 6. Follow instructions on gas flex hose - make sure you use gas pipe joint sealer only where indicated; 7. Turn gas shutoff valve back on and test for leaks using soapy water; 8. Turn on each cooktop burner to bleed out air.
Parts Used:
REGULATOR
  • Jerald from Loveland, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Wrench (Adjustable), Wrench set
Was this instruction helpful to you?