EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
Back
Back
Back
Keep typing for more specific results...
Keep typing for more specific results...
Models > TPX24PRBAAA > Instructions

TPX24PRBAAA General Electric Refrigerator - Instructions

All Instructions for the TPX24PRBAAA
121 - 135 of 286
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
water wouldn't shut off
replaced solenoid
Parts Used:
Dual Inlet Water Valve
  • James from Somerset, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set, Wrench (Adjustable)
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dispenser reservior was leaking water outlet vale also developed a leak
shut the water supply to the refridgerator unscrewed valve mount removed removed valve supply line with half inch wrench loosened and removed plastic nuts on outlet by hand unplugged both valve actuator cables. loosened two phillips screws from reservior removed inlet and outlet hoses replaced with new parts very simple repair
Parts Used:
Dual Inlet Water Valve Dispenser Water Reservoir
  • Mary from Port Monmouth, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
3 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Only crushed ice. No cubed.
Found a step by step video on YouTube made replacement very easy. Cubed ice is back. Time for a cocktail to celebrate!
Parts Used:
Ice Dispenser Solenoid Service Kit
  • JACOB from COLLEGEVILLE, PA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no ice
Removed cardboard cover from back of refrigerator with nutdriver. Removed old pump and reconnected water lines and electrical. reinstalled pump.It did take about 5-10 minutes for the pump to refill ice tray.
Parts Used:
Dual Inlet Water Valve
  • ROBERT from STOW, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Wrench set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking water valve
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
Parts Used:
Dual Inlet Water Valve
  • kathleen from red oak, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Wrench set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker overflowing. Valve stuck open
The valve I got was slightly bent up. I spent the first 10 minutes or so bending it back with my muscles. once that was done, I took off the backing of the fridge with the screwdriver, undid the single bolt holding the valve on, and unplugged it all (fridge was already unplugged). Just like everyone says, the tubing connecter is different, so I took off the old compression fittings, and pushed the tubes in. THen I hooked up the wiring... I realized that that the wiring adapter was needed but there wasn't enough room for it as is.. so I have to bend the tabs so the wiring would angle down. Everything has worked perfect since... I got Ice and no leaks! woo hoo!
Parts Used:
Dual Inlet Water Valve
  • Johnathan from Gilbert, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a soleniod and the crank assembly to got bad.
First, I had to remove the face plate where the ice and water was dispensed remove 4 screws holding the electrical circuits, disconnect circuits ,remove 2 screws holding soleniod and one screw holdin crank assembly. repace parts and screws.
Parts Used:
Dispenser Assembly Crank
  • Ronald from Chester, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispenser chute icing up
Replaced dispenser flapper
Parts Used:
Dispenser Door Assembly or Flapper
  • Robert from North Topsail Beach, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water going into ice maker
Pulled the fridge out from the wall, disconnected the power cord,turned off the water supply,removed the backing that covers the fan/motor and the two way water valve. Removed one screw that holds water valve to back of fridge,removed two water lines. Installed the new water valve , connected water lines and screw, installed back dust cover, plugged in the 110 cord, turned on the water valve. Within 30 minutes a new tray of ice cubes was ejected into the ice holding box. Mission completed.
Parts Used:
Dual Inlet Water Valve
  • Bobby A from Del City, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker only dispensed crushed ice.
Determined that the little door that opens to allow full size cubes to fall was not opening. If you open freezer door, hold door switch in, select cubes and push in the lever that the glass pushes in you should hear the solenoid lift open which opens the little door. Mine was doing nothing. Removed ice bin and then removed icemaker motor/solenoid section from back of freezer by disconnecting two wire harnesses and one screw. Found that solenoid smelled burnt and could see that inside of the solenoid was swollen out of round and burnt. Simple to replace.
Parts Used:
Ice Dispenser Solenoid Service Kit
  • Richard from THE VILLAGES, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator fan in the freezer compartment began making a loud noise.
I found a replacement evaporator fan motor and 2 mounting bracket grommets at PartSelect.com at a reasonable price. I watched the installation video provided and installed the new parts as shown in the video start to finish installation time 22 minutes.i
Parts Used:
Evaporator/Condensor Fan Grommet
  • Boyd from Rapid City, SD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost was building up inside the freezer just above the ice dispenser shute.
Followed the instructions and replaced the door recess.
Parts Used:
Dispenser Door Assembly or Flapper
  • Richard from Atlanta, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
gasket was shot
took off the panel, took out 4 screwws, took out old flap, installed new flap, put screws back in , and put trim back on.
Parts Used:
Dispenser Door Assembly or Flapper
  • HERBERT from Harlingen, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the original part had gotten a tiny pinhole in the plastic at the seam, probably due to age
After turning the water off and unplugging the refridgerator, I took the copper inlet tubing off using an adjustable wrench. I disconnected the two fuses that give power to the unit, and using a screwdriver, disconnected the water inlet/ outlet tubing from the old unit. I pushed the tubing into its proper place in the new unit, plugged in the two color coded fuses, used a wrench to reconnect the copper water tubing, and replaced the unit. EASY!!! So, easy, in fact that a non-handy girl could do it (and I can say that, being a non-handy girl!)
Parts Used:
Dual Inlet Water Valve
  • Linda from Pittsfield, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice build up in the freezer
It is a dream with less than a minute I unscrew the old part and install the new part
Parts Used:
Dual Inlet Water Valve
  • Malik from Lathrup Village, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TPX24PRBAAA