Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Parts Used:
-
Richard from Arlington, MA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
warm fridge and freezer
we had a power outage and soon after the coils in the freezer froze up I figured the defrost cycle was not working so I ordered a timer which only took a few minnutes to install, I also shut the unit down and thawed completly before turning on, frige runs like new
Parts Used:
-
rich from roberts, WI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Socket set
Was this instruction helpful to you?
Thank you for voting!
Light switch went bad
Simply stick a putty knife between the switch and refrig wall. Pop out old swith, remove both wires by pulling off switch by terminals. Throw switch out. Put wires on new switch and push into slot and all done. Nothing to it! Took me 5 minutes if th
Parts Used:
-
Joseph T. from Morgantown, WV
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Parts Used:
-
Don from Laramie, WY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
Was this instruction helpful to you?
Thank you for voting!
Light did not come on (bad bulb!) on TC18KL
I have never before seen a bulb with the filament intact not light. If the bulb's filament seems intact, screw the bulb into a known working lamp and see if it lights. When screwing it back into the socket in the fridge, it takes a bit of extra effort to fully seat (until it does, it won't light!). For replacing the switch, I unplugged the unit, used a paint scraper and worked it under the switch bezel from the right side. A bit of moxie, and the switch came out. The replacement switch had a different spade contact spacing than the original. I used a pair of scissors to cut the rubber bridge between the two switch wire connectors so I could connect to the new switch. In the end, it turned out to be the bulb. NOTE: The Model TC18KL is _not_ listed! What I finally found that the number "P7803211WL" on the sticker is actually a manufacturing code. Found this out by searching, and Sears' part search came up with matches.
Parts Used:
-
Louis from Beloit, WI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Light switch in the refrigerator was faulty from the first day we installed the fridge.
I had ordered some other parts for something entirely different off your website and service was great. So after almost ten years of a dark refrigerator, because of a defective switch, I decided to see if you had the part to fix it... You did and the part got here in 3 days. I had a working light switch and all the light in the world where my husband needed it most (in the fridge). It took me at the most ten minutes to replace the part. All is well now and I have a happy husband who can find the leftovers just fine. Thanks for your great service!
Parts Used:
-
Mary from Wasilla, AK
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was working intermittently. The ice cubes in the ice container start to melt and there was no cool air coming to the fridge side.
I removed the back cover on the freezer cabinet and discover that the evaporator coil was cover with froze and ice. I then though that one of the three component of the automatic defrost system: timer, thermostat or heater coil has stopped working. I measure the resistance off the heater coil and obtained a 54 ohms reading so that was good. I did not did a very good job with troubleshooting the timer and thermostat since I conclude that the timer was bad. I ordered and changed the timer but turned out that the faulty component was the thermostat which I replaced and the refrigerator started to work like a charm :)! The harness was not exactly the same so, I has to cut and strip two wires and reconnect; beside that everything was fairly easy to do. Thank you!
Parts Used:
-
Julio from Sun Prairie, WI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Frost buildup in the freezer resulting in warm freezer and refrigerator
I unplugged the refrigerator and defrosted the freezer. I removed the plastic grate on the front bottom of the refrigerator and removed the plate covering the defrost timer using a nut driver. I used pliers to unplug the defrost timer. Using the Instant Repairman troubleshooting instructions from partselect.com, I used a multi-tester to determine that the current defrost timer was bad. I ordered a new one from partselect.com and and received it very quickly. I plugged in the new defrost timer and screwed it back in place. I replaced the grate, plugged the refrigerator back in. It's been a week and everything is working perfectly! Easy peasy.
Parts Used:
-
Kathryn from Oregon City, OR
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Bottom freezer not cold enough
Removed bottom air vent and removed/ replaced defrost timer by removing 4 bolts with nutdriver, disconnecting the plug connections and then reversing process. Very simple. Unfortunately, this did not solve the problem. Next step was replacing the thermostat. Again a simple procedure, but required removing freezer shelves and the rear panel. You have to exchange one lead from old thermostat to new, but very simple. Again, unfortunately, it did not solve my problem. Temp still down around 24 degrees F but needs to get to about 0 degrees. In both cases, I noticed no frosting up on the evaporator coils, just a little on the tubing that the thermostat attaches to. I'm thying to decide next step. Any help will be appreciated.
Parts Used:
-
Jack from Reynoldsburg, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Freezer wasn't getting cold enough.
I followed one of the handy video's on your site and replaced the timer and now my Uncle's freezer is working again. He's happy so, I'm happy.
Parts Used:
-
Frederick from Aldan, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Parts Used:
-
David from St. Pete Beach, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezing up & ran too long
-
ted from old hickory, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
The freezer does not defrost automatically.
Replace the original mulfunctioned defrost timer by the new Defrost Timer Kit. The old timer was located in a box at the bottum of the refrigerator. You need to disconnect the refrigerator's power first. Take off the front vent panel at the bottum of the refrigerator. Use the nutdriver to unscrew the 2 screws of front cover of the box, unscrew the 2 mounting screws mount. Then carefully push the timers turning handle into the box, and pull out the timer assembly, Disconnect the '3 1 2 4' connector, and push connect it to the new timer's '3 1 2 4' terminals. Push the connected new defrost timer into the box, reverse the process to mount it back using the original screws and nutdriver. Turn on power. The freezer and refrigerator can cool down and periodically defrost automatically. The new defrost timer works great, the freezer/refrigerator works like new one again.
Parts Used:
-
ming from Seattle, WA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Freezer to Warm
Follow suggested parts to look for. Video very simple to follow repair instructions. Refrigerator back to normal.
Parts Used:
-
efrain from fullerton, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!