Heater not coming on - coil frosting up- freezer and Refrig. warm
The instructions given to me by part Select were very good.I replaced the Timer- checked the heater with oham meter it was good- checked the door weather striping it was good and replaced the thermostat with new .So at this point I may need to call a professional unless some one has another solution.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from merrillville, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer & fridge warm / condenser coils iced over
Problem not consistent. OK for 2-3 weeks, then freeze coils. Mark and observe the defrost timers manual rotating adjuster. Timer would stop mid cycle. One revolution equals 8 hours of compressor run time followed by 30 minutes of defrost. Replacing timer took 5 minutes.
Parts Used:
Defrost Timer - 60Hz 120V
  • Daniel from North Plains, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer frosted up and air could not circulate to the food section, causing the temperature to get warm, 55 degrees
I followed the procedure online and found the thermostat was ok, it had continuity when cold, and the heater coil was also ok, it too had continuity, therefore the problem was a bad defrost timer. the refrigerator works great, thanks parts select!
Parts Used:
Defrost Timer - 60Hz 120V
  • PAUL from WEIRTON, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Adaptor leaking due to old rubber washer
Turned off water. Took cardboard backing off lower back of unit. Unscrewed the old adaptor from the water distributor. Unscrewed the water hose connection from the adaptor. Put plumbers tape on new adaptor. Re-connected water hose to new adaptor and re-attached the adaptor to the water distributor. Turned water on, checked for leaks, and tightened adaptor to water distributor until leak stopped (approximately a quarter turn) after hand tightening. Easy, hardest part was pulling out the unit and putting it back in place!
Parts Used:
Icemaker Water Inlet Valve Adapter
  • Patrick from Midlothian, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Freezer Worked Fine, Refrigerator Was 47 Degrees
I went on partselect put in make and model number, a list showed the probable cause. I watched the how to video. When I received the part in short order I loosened 2 screws disconnected the wiring plug (sprayed it with contact cleaner) pluged it in, removed screws from old part put them in new one. Put timer back in its location and tightened the screws. Very eazy, works fine.
Parts Used:
Defrost Timer - 60Hz 120V
  • Allan E from Manhattan, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Overheat coils at the bottom inside of the freezer
I pick up very fast at these kind of small jobs but because of my very busy schedule I decided to call (2 times) technicians about my problem but none of them had any idea. About my repair, I removed the grill at the bottom of the refrigerator, unscrew a small plate (located on the bottom left side) that's holding the defrost timer. I plug on the new part, screw back the plate with the defrost timer and that was it. Don't forget to turn clockwise with your finger the timer until you hear a "click" and then turn it slightly more to the right. There is also a video on U-tube.
Parts Used:
Defrost Timer - 60Hz 120V
  • Costas from new hyde park, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
fridge side was getting warm.
open freezer door two screws just below unscrew slide piece to side unplug reinstall very simple.
Parts Used:
Defrost Timer - 60Hz 120V
  • Darryl from Russellville, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Parts Used:
Defrost Timer - 60Hz 120V
  • Donald from Round Rock, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fan Motor Noisy
Emptied freezer, removed fan motor cover (2 screws), removed fan and motor (2 screws), removed old motor from bracket and reassembled with new motor, transferred fan blade from old motor to new), re-installed new fan/motor (2 screws) and reinstalled cover...
Parts Used:
Evaporator Fan Motor Kit
  • Dana from Bloomington, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Parts Used:
Evaporator Fan Motor Kit
  • gustavo from gilroy, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
changed defrost timer
followed the video very esay
Parts Used:
Defrost Timer - 60Hz 120V
  • Gerry from Apache Jct, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Parts Used:
Defrost Timer - 60Hz 120V
  • Mainul from Portland, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer wouldn't go in to defrost cycle
After some troubleshooting to ensure the thermostat and heating element were working, determined that the defrost timer was the problem. With the defective part, I was able to manually advance the timer to activate the defrost cycle, but it wouldn't do so on its own. Unplugged the refrigerator from the wall. Timer is located in the refrigerator compartment at the very top. The compartment houses the cooling thermostat, the light bulb and the defrost timer. Using 1/4" nut driver, remove 4 screws holding compartment cover to top of fridge. Lower a bit to access electrical wiring. Wiring harness can be unplugged to work on the timer away from the fridge which makes it a bit easier. Timer is mounted with 2 phillips head screws. Remove screws and unplug timer from wiring. Install new timer, plug in wiring, secure with the phillips head screws and remount entire compartment.
Parts Used:
Defrost Timer - 60Hz 120V
  • John from Long Beach, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
fridge not blowing cold
bottom left cornerof fridge defrost timer replaced two bolts and a wire
Parts Used:
Defrost Timer - 60Hz 120V
  • wayne from marietta, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
both ref&frez were hot
1 went with maj 69% said defrost timer. NO. 2 went with second choice run cap NO. 3 went with my thought, ( PTC Starter ) why not, most exp part. Fixed the problem.
Parts Used:
Defrost Timer - 60Hz 120V
  • Gary from Dunnellon, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!