Refer iced up and would not keep the bottom cool. It was 70 Farenheit inside.
I simply removed 4 screws holding the casing and then 2 more holding the timer. It was very easy. I then replaced the timer by unplugging and plugged the new one in. I replaced all the screws and the job was done. Less than 30 minutes. I was very impressed with the shipping time. When I ordered the part, I had it the next day.
Parts Used:
Defrost Timer - 60Hz 120V
  • Larry from Newton, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster didn't work
Ordered a new defroster timer and replace old one. It works just fine. A $35 repair vs a $500 new appliance.
Cool.
GWE
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Eatonville, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Sunnyvale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bilb went out
replaced it
Parts Used:
Light Bulb
  • Denise from Landover, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frezzer iceing over and not cooling the refrigerator
Just removed the two screws and unpluged it.
Then I pluged the new one in and replaced the screws. It runs like a brand new reffrigerator.
Thanks for the fast delevery. Will do busness with you in the future.
Parts Used:
Defrost Timer - 60Hz 120V
  • Marcus from Pine Hill, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer built ice, fridge not cold enough and running constantly.
Removed front low grill, removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wires. Reversed process to install new timer.
Parts Used:
Defrost Timer - 60Hz 120V
  • LUIS from CENTENNIAL, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer okay, but fridge was warm
Website was great!

The defrost timer was right in front. 2 minutes and a screwdriver and I had it replaced.

To replace the thermostat, I had to take out the back panel, defrost it and then install the new part. the only problem was that the heatshrink tubing they sent was too large. Otherwise, it worked great.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • brad from minneapolis, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loud noise fan blade broke,off balance
take 1/4 hex screws out clean out dust ,remove old fan blade replace with new install bolts .
Parts Used:
Evaporator Fan Blade
  • EDWIN from ELWOOD, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer worked frig was warm. Ice maker is still not working
Removed two screws to get to defrost time pull panel down remove two screws holding time and reinstall
Parts Used:
Defrost Timer - 60Hz 120V
  • steve from Kirkland, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking water down into fridge
just like the video showed...it was excellent!!!
Parts Used:
Defrost Timer - 60Hz 120V
  • Ronald from Defiance, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Getting the light socket to snap back in properly
It snapped in place.
Parts Used:
Light Socket
  • Robert from HELENA, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coil Iceing up
took 4 screws out of the discharge vent on top of the refrigerator section and unpluged the wiring harness and put the section on the counter and unscrewed the timer and put the new one in and reinstalled the assembly and plugged the Jack and put the 4 screws back in, and rotated the timer and put it on defrost removed the back and check the heaters and drain .
Parts Used:
Defrost Timer - 60Hz 120V
  • Thomas from Stuart, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Parts Used:
Defrost Timer - 60Hz 120V
  • Donald from Round Rock, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer icing up
Part Select suggested probable causes and supplied videos of how to make the repair of a 25 yr.old refrigerator along with the specific parts to order. I was about to trash the old refrigerator but after replacing the parts for a total of about $40 and 1 hour of time it works fine now.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • James from Exton, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Freezer was not defrosting thus refrigerator was not cooling
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Parts Used:
Defrost Thermostat
  • Wayne T from Galway, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!