Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
Removed light bulb first, removed three screws, then remove plastic covering to disconnect three wires from temperature control element then replaced plastic covering, screws and lightbulb and was done. 15 to 20 minute job.
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Replaced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
ordered new retained and fastners cut to length per instructions installed repair completed thanks for your service all parts were correct and deliver on time
The hardest part was taking out original light bulb because screws on shield where hard to unscrew after all this years . The old bulb vent out leaving neck in socket. It took narrow electrical pliers to get neck out .The generic appliance bulb did not fit and had aluminum neck ,not recommended for brass sockets in ovens.Putting new light bulb in was not the problem.
removed the 2 screws that held the panel in place, had to reach up and push on locking tabs to lower trhe front of the panel. was able to then push on the locking tab of the switch to release it. removed the wires, replaced them onto the new switch, and snapped the switch into place. the rest was reverse of the uninstall process.
Part was easy to order, delivered quickly, installation very easy. Just unplug the unit, pop out the old swich using a screwdriver, disconnect and reconnect leads and pop switch back in. Definitely recommend that you can do it too.
Pry old switch and pull out. Disconect two wires. Put two wires on new switch, must be inserted right and connections not loose. Put switch in, making shure wies do not come off and snap in place
Unplug appliance. Socket wrench to unscrew two screws. Module drops down. disconnected two press-on wires by prying off with screwdriver. Removed old switch. Press-fit new switch. Reconnected two wires (color coded). Screwed module back in place. Plug in appliance.
I noticed that the refrigerator was having trouble maintaining temperature. Thought it might be time for new one until I found out that a new frig was $5k to $7K. Just happened to notice that the light switch didn't look quite right (was not sitting sqaure to the door). Once I pressed it it came loose. I then realized the the lights were staying on (50 watts of heating). Replaced the switch and the frig started working like new.
The door shelf retainer snapped in half, making the retaining bar useless.
I ordered the part online which arrived two days later. I slid the new retainer into the metal retaining bar, so that the whole piece including the prongs was inside the metal bar. Then I lined up the prongs with the holes and snapped them into place. It took about 3 minutes, and now we have our shelf back.