Door would not indicate closed
Disassembly control panel and remove switch holder; test for micro switches for continuity. Holder had broken post on micro switch holder.
Parts Used:
-
David from CARY, NC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would not heat up
-
Suzanne from POWELL, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cleaned oven with oven cleaner and it ate the old cover
Removed two Phillips screws removed old cover installed new cover secured screws. Easy Peezy
Parts select made it really easy
Parts select made it really easy
Parts Used:
-
Joseph from STATEN ISLAND, NY
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Parts Used:
-
gilbert from TOMS RIVER, NJ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Received damaged parts
The first holder locker was shipped in a soft envelope and was damaged in shipping. I ordered a second holder locker with instructions to ship in a hard container and mentioned what happened to the first holder locker. The second holder locker was shipped also in a soft envelope and was received damaged.
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
Parts Used:
-
Kenneth from APTOS, CA
-
Difficulty Level:Very Difficult
-
Total Repair Time:30 - 60 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Parts Used:
-
Jeffrey from FULSHEAR, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Parts Used:
-
Kip from POWELL, OH
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave fan would come on when the door was opened and light would turn on. Determine that the Main Interlock Switch had gone bad.
Replaced all 3 switches and Holder for all 3 switches. All is working great now.
Parts Used:
-
Daniel from HOLMEN, WI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I ordered my filter using the requested model #
Unfortunately the filter upgrade for my microwave was not a fit. When I tried it in my microwave my microwave did not work. I thought I was going to have to have a repairman come and check what was wrong. I decided to put the original filter back in and when I did my microwave worked fine. Select Parts Has issued me a refund for the purchase I made that did not work. I am at present still researching for a filter that work for my microwave.
Parts Used:
-
Kay from Lake Wales, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Parts Used:
-
johnny from port orange, FL
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
5 of 13 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Parts Used:
-
Steve from Wesley Chapel, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Parts Used:
-
Mike from BLUFFTON, SC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Holder bracket broken so Door swithch could not be activated
Part arrived next day! Thank you Parts Select. Holder bracket on older GE microwave was broken so MW would not start because door latch did not activate door switch. Removed front panel unplugged all the wiring (after I had taken a picture) to gain access to the holder bracket. Unplugged the three door switches. Removed two screws that held the holder bracket. Installed three new door switches into the new holder bracket. Positioned the bracket behind the frame and screwed back in the two screws. Snapped in this seven wire attachments, set the control panel back in the microwave and secured it with two screws. I only needed one screwdriver and one needle nose plier to remove the wire attachment from a door switch which made it easier to remove. 40 minutes.
Parts Used:
-
David from MISSION VIEJO, CA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Changing door switch
When removing a non-working door switch, you will see a hooked piece of plastic on the holder locker that looks like a latch. If you try to pull it back in order to either remove the bad switch or install a good one, it will likely break. Instead, you need to pivot the switch (It pivots on a little post which is fitted into a hole at the corner of the switch) out of position so that it is not held back by the 'latch'. Then lift the switch out. If you have to use lots of force anything, you're doing something wrong. Reverse all this when installing the new switch.
Parts Used:
-
STEPHEN from MINNEAPOLIS, MN
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
To heat a cup of coffee, user entered "10:00" instead of "1:00". Mess! After cleanup, microwave ran, but would not heat. While running, it made 2 or 3 time the noise volume as before.
I went for the cheap things first. Ohmmeter showed one of the thermostats in the magnetron compartment was open. I ordered and replaced all three thermostats. Still no heat. I took the unit off the wall (aaarrgh!) and checked the oven cavity thermal cutout. It said 7 ohms. I tested by shorting the wires together, but still no heat. So, I ordered the magnetron and diode cable. When replacing the diode cable (be sure to discharge the big cap!) either I broke it, or it was already damaged. It came off in two pieces. The new diode cable was re-enforced with thick heat shrink tubing, to prevent such breaking. You need a very short screwdriver to replace the magnetron. Now, all fixed! ~$150. A new one lists for $2000, installed in the overhead. My wife thinks I am a genius.
Parts Used:
-
G. Wayne from GARDNERVILLE, NV
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!