Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • George from McBee, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Denver from BLAIRSVILLE, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Valve was leaking water and not making ice
I unplugged the fridge and unscrewed the back cover,unscrewwd the two screws holding the water valve in place and the water line to the ice maker and the electrical connection and install the new water valve,then buttoned everything back up and plugged the fridge back in and it is working great,making ice as normal.
Parts Used:
Water Inlet Valve
  • timothy from georgetown, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
13 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Parts Used:
Light Bulb
  • ANGELA from MEBANE, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
gasket tearing
grab gasket on a corner and pull...new gasket push raised rib into grove....your Done!!!
Parts Used:
Refrigerator Door Gasket
  • Paul from AGAWAM, MA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer frosting over,fridge warm
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Brian from Otterville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker which was splashing water
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Parts Used:
Refrigerator Ice Maker Assembly
  • John from PHOENIX, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
both bulbs blown out
unplug refrigerator and insert the bulb in refrigerator first and then insert the second bulb in freezer side. After which, plug the refrigerator back in.
Parts Used:
LIGHT BULB
  • Juanita from ORANGEBURG, SC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Parts Used:
Evaporator Fan Blade
  • Bruce from MARTINEZ, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unit quit cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Parts Used:
Defrost Timer - 60Hz 120V
  • Steve from Cedar Park, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker stopped making ice and i knew it wasnt the mechanism since I could hear that working when I unplugged and plugged the unit back on.
I found a couple of videos online of a similar product fix to get a lay of the land. When I got the part, I unplugged the unit and turned off the water. It was easy to take off the back panel and remove the old water intake valve to swap it out for the new one. Once I attached everything again I could see that the valve was taking up water but it didnt seem to be going all the way to the icemaker. I gave it some time and by the next day, there was fresh ice!
Parts Used:
Water Inlet Valve
  • Jennifer from BUFFALO, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridh light bulb blew
Got sent the wrong bulb 3 times had to pay for the three bulbs 75 dollars each Sent pictures of right bulb still wrong bulb no refunds for 30 days I even gave them right part number. Found out that the part number on box but wrong bulb inside told them and they seem not to care ordered from another company still out 225 dollars
Parts Used:
LIGHT BULB
  • Sandy from DANSVILLE, NY
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Plastic Edge
Easy peasey just slipped it in
Parts Used:
Refrigerator Door Shelf Bin
  • Julie L from Eureka, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The replacement substitute stipulated and shipped to us was not compatible with this appliance.
After receipt of the incompatible LED bulb, customer service gave us the phone # of Frigidaire and they helped us to get the correct LED for this appliance. We returned the incorrect bulb to parts Select and are now waiting for a credit to our account at this point. It’s been a long process but our Frigidaire at least is now lighted.
Parts Used:
LIGHT BULB
  • Gary from CAMAS, WA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
8 loud pops and then dump ice .
Turn off power. Remove ice tray. Back out the two screws with nut driver and just lift ice maker off screws. Do not bend the water fill tube in the back . Now unplug the wire and remove ice maker .
To replace, match the color of wires on plug. Adjust wires in place and water fill tube and back on to the screws. Hold in place and snug screws. Turn power back on. In 4 to 5 hours your ice will start .
FED-EX UT to MN was 13 days to deliver .
Parts Used:
Refrigerator Ice Maker Assembly
  • Douglas from INVER GROVE, MN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?