the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Parts Used:
-
john from st aug, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
Parts Used:
-
Stephen from Los Angeles, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.
Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Parts Used:
-
Benjamin from Goldsboro, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
Parts Used:
-
Shelly from WATERLOO, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Yearly replacement of filter
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
Parts Used:
-
Robert from Myrtle Beach, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Parts Used:
-
Jodi from Benton Harbor, MI
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
brand new ge refrigerator delivered with broken access cover. cost 6.95 so i repaced it myself.
-
Gerald from Shelton, CT
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
4 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Parts Used:
-
Richard from Coppell, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
was not able to get water out of the dispenser or the ice maker
Very simple fix. Just remove the back cover, unscrew the water valve, unplug the water valve and disconnect the water line. Then reinstall the new one. Takes about 15 to 20 min and it worked like a champ
Parts Used:
-
Darren from Riverside, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set, Wrench set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser inoperative
Replaced Double Outlet Water Valve then defrosted coiled plastic water tubing at bottom position inside refrigerator into pan of hot water for 10 minutes. Water still did not flow. Defrosted refrigerator and water dispenser immediately resumed operation. Suggestion -
defrost refrigerator first.
defrost refrigerator first.
Parts Used:
-
Gregory from The Villages, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
-
Peter M. from Lincoln Park, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak from water line and value housing
Unplugged unit. Removed back cover plate. Used 5/16 water line. Cut old broken line. Used water tube union and attached new line. Removed electrical contacts. Note very easy removeand replace the red and white hookups. Next remove water line at the old vale with1/2 wrench. Hook up water line to new valve. Icemaker line was not damaged so I removed from old valve and trimmed the end. Really installed line to valve. Plugged in fridge and turned water supply back on. Check for leaks. Had trouble locatingthe 5/16 water line but found bulk. PARTS SELECT had the guest connector and the replacement valve. I received the correct parts and saved me $$$$. Plus my wife happy right before the holidays! !!,
Parts Used:
-
Joseph from Stewartsville, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Wrench set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to dispenser or ice maker.
Replacement valve fit perfectly but didn't fix the problem. More troubleshooting found blockage through the water filter assy although I don't use a filter and just have the the bypass plug installed...7 years like this. Used compressed air to blow out the line and got some crud out. Works now but can't turn water pressure up full or line hammers and stops flow. Left supply valve open slightly which supplies ice maker fine and dispenser ok. Must be something wrong with internal spring stopper in filter assy...keeps water from pouring out if filter or bypass not installed.
Parts Used:
-
Joe from Irmo, SC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser would not fill a glass completely
The trouble with DIYers is that they don't have very much experience with and the benefit of several repairs on the same appliance. So they must rely on their mechanical abilities and the youtube help of Steve. So they must resort to eliminating the variables as their diagnostic approach. In my case I was unable to find the exact description of my problem, so I began with what seemed like the most likely and the least expensive replacement. So after I had replaced the water valve, the micro switch and the main board I finally found the problem was the water filter by ordering and installing a water bypass valve which I did not have readily available at the start.
Parts Used:
-
Jay from Oceanside, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice wouldn't come out of door. It backed up in door
I followed the instructions on a posted desctiption. It workded perfectly. Replacing the inner door panel was not as difficult as described. Just start the process with the screws in the middle of the door. Those two screw holes were not slots. All of the remaining screw holes had slots. I installed all of the door screws before tightening any. I workded right the first time.
Parts Used:
-
Stephen from Richmond, VA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!