Ice Maker Door flap would not close all the way
Went on this site, found out many others like me had the flap door stuck open problem, it would not shut after you went for ice. I needed a new solenoid that opens when the ice is dispenced and closes afterwards not allowing the warm ambient air to come up the shoot which frosts the ice and melts it. It shipped QUICK and now I have a working ice maker dispenser from the outside. Its been 2 YEARS of opening the door and reaching into the ice maker bin for ice! Thanks PartSelect
Parts Used:
Dispenser Door Solenoid Assembly
  • Edward N from Boyds, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.

Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Parts Used:
Dispenser Door Solenoid Assembly
  • Benjamin from Goldsboro, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
Parts Used:
Dispenser Door Solenoid Assembly
  • Shelly from WATERLOO, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Yearly replacement of filter
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
Parts Used:
Refrigerator Ice and Water Filter
  • Robert from Myrtle Beach, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Parts Used:
LIGHT SWITCH
  • paypal_shipping_address from Ripon, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
Parts Used:
Dispenser Door Solenoid Assembly
  • Bryan from Fairfax, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Parts Used:
LIGHT SWITCH
  • Jodi from Benton Harbor, MI
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
brand new ge refrigerator delivered with broken access cover. cost 6.95 so i repaced it myself.
removed 6 screws and repaced cover.
Parts Used:
ACCESS COVER
  • Gerald from Shelton, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Parts Used:
Dispenser Door Solenoid Assembly
  • Richard from Coppell, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
was not able to get water out of the dispenser or the ice maker
Very simple fix. Just remove the back cover, unscrew the water valve, unplug the water valve and disconnect the water line. Then reinstall the new one. Takes about 15 to 20 min and it worked like a champ
Parts Used:
WATER VALVE WITH GUARD
  • Darren from Riverside, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set, Wrench set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser inoperative
Replaced Double Outlet Water Valve then defrosted coiled plastic water tubing at bottom position inside refrigerator into pan of hot water for 10 minutes. Water still did not flow. Defrosted refrigerator and water dispenser immediately resumed operation. Suggestion -
defrost refrigerator first.
Parts Used:
WATER VALVE WITH GUARD
  • Gregory from The Villages, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak from water line and value housing
Unplugged unit. Removed back cover plate. Used 5/16 water line. Cut old broken line. Used water tube union and attached new line. Removed electrical contacts. Note very easy removeand replace the red and white hookups. Next remove water line at the old vale with1/2 wrench. Hook up water line to new valve. Icemaker line was not damaged so I removed from old valve and trimmed the end. Really installed line to valve. Plugged in fridge and turned water supply back on. Check for leaks. Had trouble locatingthe 5/16 water line but found bulk. PARTS SELECT had the guest connector and the replacement valve. I received the correct parts and saved me $$$$. Plus my wife happy right before the holidays! !!,
Parts Used:
WATER VALVE WITH GUARD Union Connector - 5/16 Inch to 5/16 Inch
  • Joseph from Stewartsville, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Wrench set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
Lid Bumper
  • Peter M. from Lincoln Park, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Parts Used:
Dispenser Door Solenoid Assembly
  • john from st aug, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to dispenser or ice maker.
Replacement valve fit perfectly but didn't fix the problem. More troubleshooting found blockage through the water filter assy although I don't use a filter and just have the the bypass plug installed...7 years like this. Used compressed air to blow out the line and got some crud out. Works now but can't turn water pressure up full or line hammers and stops flow. Left supply valve open slightly which supplies ice maker fine and dispenser ok. Must be something wrong with internal spring stopper in filter assy...keeps water from pouring out if filter or bypass not installed.
Parts Used:
WATER VALVE WITH GUARD
  • Joe from Irmo, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PFSS5RKZCSS