MTB2148DRB Maytag Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
non-stick coating detioration and water overflow becoming large ice chunks
Ice maker assembly required disconnection of the wire harness at the back of the freezer and the removal of 3 hex nuts. The assembly did not come with a new wire harness nor the rigid wire attached to the hinge that can be raised to stop production of ice. The wire harness was easy to disconnect from the old assembly by pressing in on a tab. The rigid wire attached to the hinge simply required pulling straight out of the hinge-hole (no need to twist, slide, or perform other contortions...it does require significant force to remove, but it does pull straight out). It was simple to attach it to the new ice assembly. Reinstalled the 3 hex nuts and wire harness plug and was good to go....after waiting several hours! I was worried at first because the unit did not immediately fill with water after I plugged the fridge back into the wall socket. However, after the freezer was cold enough, the water did run and I had my first ice dump within about 3 hours of finishing the installation. We have good ice again, and Partselect has excellent pricing and awesome delivery! I received the unit the day after ordering, and I had only paid the basic shipping! Thanks Partselect! Jeff
Parts Used:
-
Jeffrey from Murphy, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker was leaking
I read the previous repair story and agree with the author that the screw behind the front piece was difficult to remove and re-install. If I had a magnetized nut driver I think it would have been easier. There were no installation instructions so I relied upon the repair experiences. The other two screws came out easily and I found the harness release easily and the harness was easy to reinstall.
I am not a good handyman but was able to install the new ice maker
I am not a good handyman but was able to install the new ice maker
Parts Used:
-
Jay from Richardson, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Black flecks in the ice
I made use of instructions for other users, see 'My ice maker has been shedding.....' and they were very helpful. The one problem not covered - the instructions that came with the new icemaker said to 'remove the bearing and inlet from the old icemaker and install in the new icemaker', but gave no instructions for how to accomplish this.
The old inlet has a square opening in the back and a u-shaped knockout in the side. The new one has a round opening in the side and square knockout in the back)
After several attempts to remove them, I gave up and used the new inlet with the knockout removed. I did not attempt to cover the side opening and it worked fine that way - no leaks.
The old inlet has a square opening in the back and a u-shaped knockout in the side. The new one has a round opening in the side and square knockout in the back)
After several attempts to remove them, I gave up and used the new inlet with the knockout removed. I did not attempt to cover the side opening and it worked fine that way - no leaks.
Parts Used:
-
Jon from Leander, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stalled out, made excessive noise trying to evacuate completed ice cubes
There are basically three screws that hold the unit in place on the inside of the freezer. Removing them is relatively easy, and the unit is replaced with the same three screws. You do have to use the formed metal wire from your old unit, so don't throw it out! You also have to use the wiring harness from your old unit.
Parts Used:
-
Mike from Clemson, SC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
Parts Used:
-
Mark from Farmington Hills, MI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker made some pretty sad cubes! Hollow, unfilled, or small cubes
Replacing the icemaker is pretty simple. Three screws, an electrical connector. Hardest part is getting to the icemaker since the freezer is below the refrigerator.
Parts Used:
-
Dana from ABINGTON, PA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would short cycle after overload tripped
Test original overload with meter to see if voltage drops out when overload trips. It did. Measured amp draw to verify compressor load was with in range, it was. New overload no longer trips during compressor start up.
Parts Used:
-
Eric from VALLONIA, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Parts Used:
-
Karl from Wellesley, MA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My ice maker went out, I decided to replace the single outlet water valve as well.
removed the cover from the back of the refrigerator, and used the nutdriver to loosen screw on the single outlet water valve, removed the old water valve and the hoses to it. Connected the hoses to the new valve and attached to the wall of the refrigerator by tightening the screw. Then removed the old ice maker from the inside of the refrigerator, by loosening the two screws and attached the new one, I tightened the screws and then I was done. It is working great.
Parts Used:
-
Patricia from Pearland, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Wrench (Adjustable)
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I went by the video but my removal and installation were different than shown.
Instead of the ice maker unclipping from the wall after one 1/4" screw being removed from the bracket, I had to remove three of the 4 Phillips head screws from the ice bucket slider below the ice maker and swivel it down to allow the ice maker bracket to clear. The two 1/4" screws holding the ice maker to the wall at the top had to be removed and then the ice maker could be pulled away from the freezer wall. The rest of the instructions went according to the video and went well.
Parts Used:
-
Gregory from GARNER, KY
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quit making ice
Loosen the screws on the sidewall (don't take them all the way out and drop them on the floor as I did) and remove the screw from the bottom bracket. Change out the electrical wires and the wire level sensor that does not come with the new unit. Put the new one in place and give it some time to cool down and make ice ( don't be impatient like I was and think the new unit was bad or that you replaced the wrong part)
Parts Used:
-
James from Charleston, SC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
Parts Used:
-
David from Granada Hills, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Parts Used:
-
craig from maple grove, MN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Parts Used:
-
John from Greensboro, NC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
difficulty unplugging the power pigtail
-
William from Las Cruces, NM
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!