EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
Back
Back
Back
Keep typing for more specific results...
Keep typing for more specific results...

LD301 LG - Overview

Models starting with LD301

Keep searches simple, eg. "belt" or "pump".
Sensor – Part Number: 6877A30013V
Sensor
PartSelect #: PS3654111
Manufacturer #: 6877A30013V
Also known as thermistor.
  No Longer Available
Switch Assembly – Part Number: 6600A30003C
Switch Assembly
PartSelect #: PS3529251
Manufacturer #: 6600A30003C
  No Longer Available
Connector,Hose – Part Number: 5214A20027B
Connector,Hose
PartSelect #: PS3527251
Manufacturer #: 5214A20027B
  No Longer Available
Roller Assembly – Part Number: 4441A30001B
Roller Assembly
★★★★★
★★★★★
(1)
PartSelect #: PS3522978
Manufacturer #: 4441A30001B
  No Longer Available
THERMISTOR,NTC – Part Number: 6323A21001A
THERMISTOR,NTC
PartSelect #: PS11706490
Manufacturer #: 6323A21001A
  No Longer Available
Filter,Air – Part Number: 5230A20040A
Filter,Air
PartSelect #: PS3527502
Manufacturer #: 5230A20040A
  No Longer Available
Fan,Turbo – Part Number: 5900A20007A
Fan,Turbo
PartSelect #: PS3528579
Manufacturer #: 5900A20007A
  No Longer Available
PCB Assembly,Display – Part Number: 6871A20600A
PCB Assembly,Display
PartSelect #: PS3529789
Manufacturer #: 6871A20600A
  No Longer Available
Tank Assembly,Bucket – Part Number: 4839A10002G
Tank Assembly,Bucket
PartSelect #: PS3523971
Manufacturer #: 4839A10002G
$85.94
  Special Order
SENSOR ASSEMBLY – Part Number: 6877A30013S
SENSOR ASSEMBLY
PartSelect #: PS3636689
Manufacturer #: 6877A30013S
  No Longer Available
PCB Assembly,Main – Part Number: EBR36909303
PCB Assembly,Main
PartSelect #: PS3533771
Manufacturer #: EBR36909303
  No Longer Available
Cap – Part Number: MBL64799901
Cap
PartSelect #: PS8770751
Manufacturer #: MBL64799901
  No Longer Available

Common Symptoms of models starting with LD301

[Viewing 2 of 2]
Unit says bucket is full when it isn’t
Fixed by
these parts
Fixing Fixing
Show All
Won’t stay on
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
bucket full light constantly blinking with error code 01 on the display
Unscrew and detached front and back panels, and inside framework holding the sheet metal to the body, after removing the sheet metal, unscrew the box enclosing the control board, use needle nose pliers to unhook the sensor module from the board and place the new sensor into the spots where the old sensor was connected (thermostat area, humidity Sensor, bucket switch, and control board). Close up the unit and your good to go.
Parts Used:
Sensor
  • Seif from DETROIT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
turbo stopped spinning
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
Parts Used:
Fan,Turbo
  • Cheryl from Bradner, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Problem: The display was showing a CH01 error code and the bucket full light was blinking. Research: 1) It could be a bad thermistor. 2) The error code indicates an electronic abnormality.
Action:
1. Remove the back cover from the dehumidifier. The tricky part will be the two hidden clips located under the top edge.
2. Remove the front cover. The front cover is constrained by the wire leading to the thermistor. The thermistor is located to the left of the cooling fins inside a copper tube. I used a small screw driver to push the thermistor from the top and out the bottom of the copper tube. Once removed, the front cover opened up from left to right.
3. Under the front cover, behind the control panel is a black cover. Remove the four screws on the black cover and remove the cover. Remove the four screws holding the circuit board and remove the circuit board.
4. Unplug the thermistor from the circuit board. Using an ohmmeter, test the thermistor: http://www.learningaboutelectronics.com/Articles/How-to-test-a-thermistor.php My thermistor tested good.
5. Visually inspect the circuit board. My circuit board had small black spots scattered about the circuit board. I took a clean dry brush and removed the small black spots. I suspect it was mold. I reassembled the electronics and turned the dehumidifier on. To my surprise the CH01 error code was gone and the dehumidifier appeared to be working. However, after further testing I discovered some of the buttons were not working. To me, this at least identified the failed part.
6. I ordered the circuit board from PartSelect: Item Number - PS3646093, Description - PCB ASSEMBLY,DISPLAY. This is this circuit board located under the control panel / display.
7. I replaced the circuit board. The dehumidifier is working well. All is good.
Parts Used:
PCB ASSEMBLY,DISPLAY
  • CHARLES from MINNETRISTA, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?