Unplugged refrigerator, Removed lower back panel, Removed fan from fan bracket, Installed new fan to fan bracket, Installed new wire assembly to fan, Replaced back panel. Plugged refrigerator back in and it works great. Only tool needed was 1/4" socket.
where the wires crossed at the start relay, 20 years of vibration allowed them to short out and burn out the start relay ..since i have 2 identical fridges i switched the run capacitor to determine it was'nt bad too...ordered a start relay wednesday nite and got it friday morning...cold fridge by noon...good service and the part was exactly the same as the original....
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Refrigerator would not cool down. Evaporator fan inop.
Unplug, then remove shelving and rear panel. Remove fan motor, swap wired and install new motor. Reinstall in reverse order. Plug back in and verify the fan is running. Easy and nothing special. Only thing I would caution is they use a foam runner to the refrigerator that may be iced up. Carefully clean the ice out before reinstalling everything. A follow up note. If the fan has not been running, Ice will build up in the drain tube. When you start up the refrigerator, you will see water dripping into the lower shelf. This is easy to fix. Unplug refrigerator and disassemble to where you can see the coils. There will be ice on the bottom covering the drain line hole. You will need to carefully chip away the ice, then use a hair dryer to melt the ice. Carefully use a pointed tool to push in the drain tube until the water drains. Go slow and be patient. Heat is your friend when doing this.
Intermittent performance, then Frig. quit completely.
Hesitated for a month. Bought part most likely to have failed. Almost instant delivery (as always). Put in part in 15 minutes (including taking cover off). Turn frig. on. First nothing, then in a few minutes it cranks up -- oh, how beautiful. It's been working perfectly ever since. Thanks for being great help!
freezer constantly covered with ice not defrosting
I opened rear wall inside freezer (two screws) cut the wires on old thermostat and removed it. Then I attatched the new thermostat to the existing wires using wire nuts and electrical tape and slid it onto the copper tubing. Re-installed the rear wall. Freezer works like a charm and the refridgerator is also colder. Job completed in twenty minutes and Tim Allen has nothing on me. Mike Milne
Leakiong water from the freezer compartment into the lower refrigeration compartment
After unplugging the appliance, I unscrewed the screws in the bottom and the back of the freezer compartment and un-clipped the connector for the ice machine, which i do not have installed. I clipped the pink and brown wires and replace the switch with the new switch. unfortunately, the appliance is still dripping water from the freezer compartment. It worked for a couple of days then stopped working. Still looking for a true FIX.
broken track for veg. trays on 10 year old refrigerator
Slipped track into grooves, and wha-la!! Easy fix, quick order turn-around, part realidy available for a ten year old appliance. Overall, could not have been a better experience.
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Took part out of box..Took old part off and installed new part .. Plugged in Refrigerator.. so far is operating great performance..Thank you for shipping in record time..you made this sitution painless ..will definitely recommend to all my friends to shop with PartSelect first .. Thank you so much.. It was one of the hottest day of this summer and for my Refigerator to go was a horrible thought.. with your shipping and reciveing this part was a perfect ending to a bad day... Gina Hayden
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced. reassembled the pieces.
First I removed the old hardware from the door and reused the screws that I had to replace the handle. very simple swap. handle was not shipped with screws so hope you have yours.