HTM18GCSDRSA Hotpoint Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Parts Used:
-
Robert from Coto de Caza, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken freezer door shelf
-
Chris from E NORTHPORT, NY
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace broken door dairy
-
Edwin from BELLINGHAM, WA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
Parts Used:
-
KEITH from WINDER, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
5 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The unit cycles but does not achieve proper temperature
Remove power from the unit. With short length #2 Phillips loosen and remove the two(2) screws on the control panel located center top of the refrigeration area. Slide the control panel back about 1/2 inch and allow it to dangle from its wiring harness. Pinch the locking tab on the harness connector with one hand and use the other hand to separate the two sides. A little force is required. Remove the control panel from the refrigerator and shut the refrigerator door. Examine and note the routing of the temperature probe (Silver colored flexible wire) take a picture for later reference. Remove the old and replace with new unit. route temperature probe like the replaced unit. Reverse the steps and reinstall the control panel. It is a good idea to also purchase and replace the defrost timer.
Parts Used:
-
Anthony from COVINGTON, LA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the frame was broken and it made using the shelf for food storage difficult.
Emptied the lower area of food, removed the drawers and the removed the broken shelf frame. My glass was unbroken so after removing it from the broken frame and cleaning it, I just had to place it in the new frame and put it in the frig. Can't believe how easy and quick the whole process was. I can now utilized all that wasted space in my frig again.
Parts Used:
-
martha from Lehigh Acres, FL
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Shelf retainers were broken from use in Rental house
-
Alecia from COVINGTON, WA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Parts Used:
-
Lynn from MOUNTAIN HOME, ID
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge never cuts off.freeze everything inside of fridge.
To remove the temp sensor.2 Phillip head screws not remove the cover inside fridge .the temp control knob cover.removed that and unplugged switch.installed new switch.reinstalled cover.
Parts Used:
-
Henry from DOUGLASVILLE, GA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I never had Door shelving
Just popped them in their slots. Very easy and it made my refrigerator brand new again.. Thank you
Parts Used:
-
Jennifer from TEXARKANA, AR
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken freezee door shelf
-
Sophie from WASHINGTON, DC
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
missing part
I order the small part and installed it myself, it was very easy with "part select". I will refer them and use them in the future. Thanks parts select.
Parts Used:
-
james from humble, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condensor fan blade cracked, blade was sheared off.
First, remove the cardboard cover on the back, lower portion of the refrigerator.
Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)
Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.
Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.
Reverse the above steps to attach the new blade.
Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)
Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.
Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.
Reverse the above steps to attach the new blade.
Parts Used:
-
Bradley from Cedarburg, WI
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Could not adjust temperature
-
Boyd from Blaine, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
icemaker stripper fall a part
instalation was very easy - but the part was 3/4 inch to long and a 1/32 inch to wide.Trimmed it with the "faithfull"
Dremel and it works!The instalation part of the "job" was less then 10 min.
Dremel and it works!The instalation part of the "job" was less then 10 min.
Parts Used:
-
Ted from Harrisonburg, VA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!