Water under refrigerator, leaky ice maker water supply solenoid valve
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve in the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Parts Used:
Refrigerator Outlet Valve Kit
  • Eric from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rack holding vegetable trays were broken.
Simply changed the part.
Parts Used:
Vegetable Drawer Shelf Frame
  • Ernest J from Slaughter, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice in freezer running down sides
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.

Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
Parts Used:
Defrost Timer - 120V 60Hz
  • P. Michael from Tustin, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer stopped working
I noticed that if I unplugged the refrigerator and plugged it back in a while later it would start working but eventually would stop. I deduced the problem was likely the defrost thermostat. I ordered the thermostat but it was in a difficult place behind the evaporator coil which I could not remove. While I was trying to work it into position my hand pressed against the defrost coil and shattered the glass sheath. I ordered the coil and finally managed to get it and the thermostat installed. The refrigerator seems to work fine now.
Parts Used:
Defrost Heater
  • Clifford from Melbourne, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost system kept freezing up
took out 4 screws - lowered timer cover - replaced timer- put it back together
Parts Used:
Defrost Timer - 120V 60Hz
  • Robert from Williamstown, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
Parts Used:
Defrost Timer - 120V 60Hz
  • Ben from Warrior, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Parts Used:
Light Bulb - 40W
  • Barbara from BELLEVUE, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
15 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no water in ice maker
Change out water valve.. to find out my temp setting was to high. My kids changed the setting.. so my ice maker didnt work. The water valve will not open until it senses the right temp. Hope this help someone. But my part was here the next day
Parts Used:
Refrigerator Outlet Valve Kit
  • O.J. from SUFFOLK, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator wasn't cooling but the freezer was working properly
From instructions found on the site I was directed to the defrost timer part being bad. And from the information others posted that have had the same problem I was able to replace that part by removing the bottom grill just below the door and on the left side was the part. Removing one screw to remove the bracket from the frame and then another screw to remove the part from the bracket. I found it easier to remove the part from the bracket before I pulled the part out so I would have more room to unplug the connector. Just reverse the steps to replace the new part. It took about a day or so for the refrigerator to get to the proper temp.
Parts Used:
Defrost Timer - 120V 60Hz
  • Don from BELLVILLE, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bottom door hinge was lost during move
I had lost the bottom hinge during a move and so I rigged the hinge using an old tv antenna and the door never really quite worked right and it was VERY annoying. I stumbled upon this site and was surprised how inexpensive the part I needed was. I was very impressed with the speed of shipping and the install took maybe 5 minutes. The fridge works as good as new. Thanks a ton!
Parts Used:
Refrigerator Hinge Bottom Pin
  • Dustin from Marlow, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no water to icemaker
turned off water supply, took screws out of bracket, then unhooked water lines. Installed water lines onto new valve, plugged it in then screwed bracket back onto fridge, turned on water and was back operating
Parts Used:
Refrigerator Outlet Valve Kit
  • Ron from Clinton, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Parts Used:
LIGHT SWITCH
  • robert from FRANKLIN SQ, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no shelf in my freezer
first I ordered parts that didn't work. the return process was painless and I found the part I needed, which just popped right in!
Parts Used:
Freezer Shelf
  • Barbara from Brookfield, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker barely working
Repair was very simple. Removed refridgerator bottom back panel, about 6 or 7 screws. disconnected bad valve, installed new valve , connected water supply line and then reinstalled panel. Took about 15 minutes from start to finish.
Parts Used:
Refrigerator Outlet Valve Kit
  • William from Provencal, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Parts Used:
Ice Maker
  • Ron from ORANGE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!