Fan was noisy and finally quit. Top of freezer was 50, bottom of freezer was freezing.
First I removed the top shelf, ice drawer and second shelf. Next, I used a 1/4" socket and removed the three screws holding the ice maker lower unit, unpluged and removed from unit. I removed the light cover revealing two screws. I then removed the plastic unit holding the fan. I unpluged all plugs and uncliped the white sensor from the back coils. Once the fan was out, I replaced it with the new one by unbolting the fan bracket and putting the new one in place. I clipped the new sensor in place and replaced all the parts in reverse order. I saved $200 in repair costs thanks to PartSelect.com.
Parts Used:
Evaporator Fan With Thermistor
  • Richard from Pretty Prairie, KS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
25 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Refrigerator both warm, frost buildup on freezer coil cover
De-iced cover and removed two phillips head screws and two 1/4 " nutdriver screws to expose coil, defrost heater and defrost thermostat. Deiced the coil and surrounding area with a heat gun. Removed two screws that hold the defrost heater in place, disconnected the wires to the original heater. The original assy. was a single quartz and the new one was a double quartz. This required rerouting the left wire along with the right one, but was no problem as the wire was plenty long enough. Re-installed the assy. with the two screws. I replaced the defrost termination thermostat, even though it tested good, because I have had experience in that it would be the next to go, and not to in-convenience the owner in unloading the fridge a second time. The only difficult part was fitting into the freezer compartment. As usual, order by 3p.m. and shipping is the same day and is a real joy to use Partselect.com
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat
  • James from Au Sable Forks, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
20 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wouldn't defrost
Unplugged refrigerator, removed cover, defrosted with heat gun, replaced Defrost Thermostat, and replaced single element with double element Defrost Heater. All went very well with minimal difficulty, and instructions that accompanied parts along with the instructional video on your site, made the repair quite easy. The repair is going on the 4th week now, and no freeze up yet.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat
  • Aaron from Walnut Ridge, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
20 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
LIGHT SWITCH
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
26 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor does not run
The first component I suspect is the relay mounted near the compressor. I installed the replacement relay and still nothing. I then removed the control board, inspected it for burnt circuit paths or components. I noticed the c.b. relay for the compressor's lead had burned away the solder and there was no longer a viable connection. Not sure why this happened but my next step is to a) reestablish a solder connection. If this fails then b) replace the control board.
Parts Used:
Refrigerator Ptcr
  • Craig from Soldotna, AK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
26 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator wasn't cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires, it was really simple. I conected the new element & defrost themostat (instuctions were included with the parts). I replaced the cover pluged the fridge in everything was woking fine. I placed a themometer in the fridge & have been watching it for 2+ weeks now it is working fine. To anyone who is looking to do this repair, on thier own, I reccomend it. It was very simple & required little to no skill. No reasopn to throw away money to call a repair man.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat
  • James from LaGrange, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dairy Door Cover had cracked
Repair took about 5 seconds. No directions necessary. Super easy.
Parts Used:
DOOR DAIRY
  • Stephanie from Tampa, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
21 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loss of refrigeration
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...

Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.

With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.

With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.

With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.

Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...

NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Parts Used:
Defrost Heater Harness Kit
  • Heather from Pennington, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Parts Used:
Evaporator Fan Motor
  • Jason` from Colchester, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud knocking noise with the evaporator fan
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).

I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.

All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.

Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.

The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
Parts Used:
Evaporator Fan Motor
  • lk from carlsbad, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
"Moaning Myrtle" syndrome. Refrigerator makes a whooing sound for hours at a time
Checked the internet for reports of similar problems and concluded that it was probably the main control board. Not being particularly handy, I would never have attempted to change the board myself if I had not read the comments and instructions from people on this site. Thanks.

The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.

The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.

I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
Parts Used:
Main Control Board Assembly
  • Stephen from Spring, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge wouldn't cool, frozen food thawed
First my wife and i took the panel off the back, unscrewed the old mainboard, unplugged all the switches from it and prayed that the new one would work. We were without a fridge for 2 weeks beginning 2 days before Christmas!!!!! Gingerly, we put the new board in place, screwed it into the fridge, connected the switches, attached the ground wire, and held our breath as we plugged it back in. Within seconds, the familiar sound of water filling the icemaker was hear and there were cheers all around!!!
Parts Used:
Main Control Board Assembly
  • John from Milford, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
LIGHT SWITCH
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
19 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Parts Used:
Light Bulb - 40W
  • Leo from TWIN FALLS, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
22 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
LIGHT SWITCH
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!