GSH25IGRBBCC General Electric Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer intermittently thawing and refreezing.
Local repairman was called. He replaced the condenser fan motor as it had an intermittent noise several days before. Cost of the repair was 252.00. Two days later freezer was thawing again. He then came back again and said it was probably the evaporator fan and would replace it for 339. dollars or the mother board which he would replace for 500 dollars. He recommended replacing the unit. Since my unit was still in pristine looking condition I decided to do some further research. That is when I found your web site. After reviewing the possible causes on your site I ordered the defrost themostat and and all three thermistors.As a precaution I also ordered the evaporator fan and defrost heater and bracket Assembly. When the parts arrived I disconnected the power to the unit. Removed the shelves and lower pan. Removed the light shield and light bulb. Reovede the two screws holding the evaporator coil cover. This allowed access to the evaporator themostat. I then cut the wires from the old themostat and removed it from the coil. I then stripped the wires on the colored wires and also cut the wires on the new themostat and stripped those. Then using wire nuts I aatached the wires making sure they were properly color coded. Wrapped with electrical tape and attached the new thermostat to the evaporator coil. I then located the evaporator temperature sensor and removed it from the coil and removed the clip and placed it aside for use on the new sensor. I cut the wires and discarded old sensor. Stripped wires on the new sensor after determining the proper length and stripped the wires where the old one was removed and the using in line connectors I first crimped the wires on the new connector and the crimped both wires to the wires previously cut and stripped. Reinstalled the connector to the clip and clipped it back onto the evaporator coil. I then disconnected the wires attached to the defrost heater bracket assembly, located the two screws holding it to unit and removed it from the unit. I did a continuity check on it and it checked ok but was black so I replaced it as a precaution since I already had a new one. Hung the new unit onto the mounting bracket reinstalled the two mounting screws and reattached the two wires. Reinstalled the evaporator cover making sure to reattach the ground wire clip. Reinstalled screws and light cover and all shelves and pan. Reconneceted electrical power. Unit operated fine for a couple of days and then thawed again. I then retraced the steps removing what I had to remove to replace the evaporator fan motor and replaced it per the installation instructions on your site. The unit has now been operating for five days maintaining -8 degrees in the freezer and 37degrees in the refrigerator. I probably could have done a little more trouble shooting at the main board but didn't want to risk damaging that since I already had the parts I thought would fix the problem if it wasn't the main board. I only replaced the one temperature sensor so I will probably return the two I did not use. Thanks for your excellent "how to"videos.
Parts Used:
-
Donald from HAINES CITY, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Socket set
9 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Will not make ice
-
GEORGE from ELIOT, ME
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
13 of 23 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge not cold
On this fridge, you MUST take out the ice maker. First took out the shelves. Then take out the ice maker. This is done by taking out the four screws on the side that hold the assembly containing the bulb. Then there is one screw that holds that assembly to the icemaker. Do not take out any other screws, this is a mistake I made that cost me a few more hours figuring out how to get the other parts to mount correctly to the assembly containing the bulb. The icemaker should lift right out once the white plus is unplugged from the assembly that holds the light. Then took out the shelf brackets and finally could remove rear panel. Found it all iced up as others have. Took 1.5 hours to manually defrost while using sponges to sop up all the water that would run into the drain if you let it. Was about a gallon of water so using sponges worked well. Heater was open when checked with a meter, but you could tell it was blown by the way it looked. All cloudy. Put things back in reverse order. Had an issue with the icemaker shooting water out and missing the icemaker. Eventually was able to align better. This fridge had also just stopped dispensing water. I think the lines may have been frozen in the back, because one day after defrosting manually, the water dispenser started working again Overall this took about 4 hours. But a few days later, the water dispenser again stopped working. Not sure about that one. I have a valve already that I will try for this issue but somehow I don't think its the valve.
Parts Used:
-
Christopher from Perkasie, PA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
9 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker making no ice
I first replaced in-line water filter to the fridge. No ice. Then I replaced the water filter inside the fridge. Still no ice. I inspected the water inlet feeding the ice cube trays and it was froze up with ice. I removed the two screws holding the ice maker in place to remove the ice from the inlet tray. I then used a hair dryer to melt the ice accumulated in the in-coming water tube. Turned off the water and unplugged the fridge. When replacing the old water valve, I first blew through the hose feeding the ice maker to be sure that it was clear of ice. After re-attaching the water hoses and the electrical connections, I turned on the water, plugged in the fridge and turned the ice maker switch back on. Next morning I had ice cubes. Only mystery is I am not hearing the usual water noise when water is feeding the cube tray like I did before, - not to worry though if it works. My drawer is now full of cubes.
Parts Used:
-
Larry from Raymond, NE
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
9 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser would not shut off when you released it. It would spill water and run for ten or twelve seconds after removing glass and releasing dispenser.
Ordered the new part (water valve). Took off the bad one followed directions on you video. The video explained the process making it easy to do.
Parts Used:
-
Jose from La Vernia, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Wrench set
8 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The eavporator coils were completely frozen which prevented fridge-freezer air circulation
1. Removed all food, shelves, and ice bin from freezer compartment.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
Parts Used:
-
chris from GROVE CITY, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
7 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Vegetable Crisper Pan
This was a simple repair. I removed the broken bin from the refrigerator and snapped the white plastic handle / humidity control slide off the broken bin and snapped it onto the new bin. I replaced the bin in the refrigerator and loaded it up with veggies. Took all of 5 minutes to make the repair.
Parts Used:
-
Gary from Andover, KS
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
9 of 13 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporate coils freezing up-refrigerator/freezer warm
Level of difficulty, as far a mechanical skill goes is relatively easy; however, everything in the interior of the freezer (including icemaker) must be removed to get to the defrost thermostat. The defrost heater only needs the racks and back panel removed. It probably took about 45 minutes with a heat gun to melt the ice off of the coils so that I could work on it-need lots of towels/rags to pick up the water.
Parts Used:
-
JAMES from HENDERSON, CO
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers, Wrench set
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Right side drawer slides broken.
Total time to replace both slides was ten minutes. It took me longer to take the stuff off the shielf than it was to fix the slides!
Parts Used:
-
Nicholas from Twinnsburg, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water in door dispensor quit working
First, I turned off the water supply line to the refrigerator from the house at the wall and unplugged the power cord. Secondly, I removed the small screws that hold the piece of cardboard over the opening in the lower left corner (rear of the refrigerator) by the compressor. Thirdlyl, I removed the other end of the water line where it attaches to the water valve with an adjustable end wrench. Then I removed the small screw that holds the double water outlet valves to the refrigerator frame. I then removed the water valve by pulling it out of the rear of the refrigerator, unplugged the electrical connections, and cut the water lines where they enter the valves. I then plugged the electrical connectors into the new valves and pushed the hoses into their respective openings. These are one-way connectors - once you push them in (firmly) they will not leak or come back out. All I did then was replace the valve and secure it with the one little screw and then replace the cardboard piece onto the rear of the refrigerator. Don't forget to turn the water supply back on. That's it!!
Parts Used:
-
Richard from Temecula, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Wrench (Adjustable)
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old door gasket wasn't working
We soaked the new gasket in warm water for a while and we pressed it into place. Really very easy. Working fine again.
Thank you!
Thank you!
Parts Used:
-
Stan from BUFFALO, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
6 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak on floor
pulled out refer. found leak at corner lower back, pulled off lower cover. found valve for icemaker leaking. looked in owners/inst guide, pulled up on computer, identified part, called, order overnight part. recieved part & installed, repair complete & successful.
Parts Used:
-
Gerald from Colorado Springs, CO
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Socket set, Wrench set
6 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water dispenser was slowly leaking
Shut off water supply. Unplugged refrigerator. Removed cover. (6 screws -- nutdriver will come in handy). Removed screw securing water valve to frame (again the nutdriver). Unplugged red and white power connectors to solenoids. Using channel locks, loosened nut holding main water supply to valve and removed. Depressed compression fittings to valve and pulled out plastic water lines that supply water dispenser and ice maker. Reconnected main water supply to new part. Pushed both water lines into respective fittings of new part. Reconnected power supply to solenoids. Attached new part to frame with screw. Replaced back cover. Turned water supply back on. Plugged refrig. back in. Problem solved! Savings = $300!
Parts Used:
-
Robert from Huber Heights, OH
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers
6 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Peter
Parts Used:
-
Peter from Kalispell, MT
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
7 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water from the dispenser
I pulled-out & unplugged the refrigerator. Removed the screws to gain access through the lower back panel. The water valve is on the left side as I face the back of the fridge. It has one screw holding it to the frame of the fridge. Once it is free, the main water hose is unscrewed and the two out-let lines were pulled-out. If your valve was not ruined prior to this, it is ruined now, as the lines will not re-seat. Then everything is done in reverse order. I did cut 1/2 inch off of the two lines so that they reseat into the new valve. Just push into the valve and they are good.
Parts Used:
-
Anthony from Carmel, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Wrench (Adjustable)
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!