Keep typing for more specific results...
Models > GI1500XHT9 > Instructions

GI1500XHT9 Whirlpool Ice Maker - Instructions

All Instructions for the GI1500XHT9
61 - 75 of 130
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
noise coming from back of refrigerator. determined it was the fan
Unplug regrigerator power cordfrom wall outlet. Using nut driver remove cover from lower back side of refrigerator. Unplug wire connection to fan. Using nut driver remove the four screws holding the fan/bracket assembly. Carefully remove fan/bracket assembly from refrigerator. Using nut driver,remove the old fan from fan bracket. Using nut driver install new fan on fan bracket. Carfefully install new fan/bracket assembly and install the four screws. Plug wire connection to fan (you may need to use adapter supplied with new fan). Reinstall refrigerator lower back cover. Plug refrigerator power cord back into outlet. Note: you may wish to carefully vacuum dust from back of refrigerator before installing back cover. You should also vacuum dust from front side.
Parts Used:
Condenser Fan Motor Kit
  • BRUCE from SOUTH WINDSOR, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor had stopped working
I found the part I needed on this website, watched the tutorial and saw how simple it was to do myself. I ordered the part and it arrived within a few short days. It took me no more than 15 minutes to change out the part. I saved myself several hundred dollars. It is rather shocking how much the "professionals" charge considering the cost of parts, labor and nominal service fees.
Parts Used:
Condenser Fan Motor Kit
  • Marshall from Garland, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cold. and keeps striping the circuit breaker and shutting off other appliances using the same circuit.
what I discovered is the condenser fan is still operating but not strong another word insufficient cooling for the condenser. therefore, it's getting too hot and shutting off and stripped the circuit breaker. After installing the new condenser fan, it gets back in business. it's quite simple. Just unplug the unit off, uncover the bottom back cover and there you see compressor, condenser fan and other good stuff. there you unscrew the nut in front of the condenser fan and remove the fan, then it expose the two screws that holding the fan motor, remove these screws and take out the motor. and just install the new fan motor kit in and there you have it. plug it back to the wall and there it goes
Parts Used:
Condenser Fan Motor Kit
  • kevin from Antelope, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Very noisy when condensor fan came on
I've tried ordering the part from Sears and they told me it will take about 7 days for the part to arrive, some other place said it will overnite for extra money. So I've ordered the part from Part Select at a good price and prompt delivery. once the part arrive installing the part so so easy cause it had easy to follow instructions.
Parts Used:
Condenser Fan Motor Kit
  • manuel from wilmington, DE
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not make Ice.
Took out one strap support with a nut driver, unplugged the device and plugged in the new one. Reinstalled the support strap. Job complete.
Parts Used:
Thermistor
  • Paul from Paige, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Wire in ice cutter assembly had broken
Removed old assembly by disconnecting 2 wiring harness connections and loosening 2 screws with nutdriver. Installed new assembly using same process. Had ice in about an hour. Very easy.
Parts Used:
Complete Ice Cutter Grid Assembly
  • Paul from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
macnine was producing ice but would not cut into cubes
remove the front cover by removing two screws. then remove two screws with a nut driver on each side. unplug the wireing harness from the top of the unit (may need pliers for this) the pull the unit out. then slide the new unit in, connect the wireing harness, install two side screws, and install the front cover and wham you will have ice in about 30 minutes. thanks parts select. you were very easy to deal with
Parts Used:
Complete Ice Cutter Grid Assembly
  • ALAN from KENNETT, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Inlet water valve restricted with debree.
Open appliance door. Removed access plate at lower front (two screws). Removed two screws holding valve in place. Depressed water line retainers and removed water lines from valve. Inserted water lines in replacement valve, remounted valve, reinstalled access plate. Tested operation. (I did install a water filter during the repair to prevent reoccurrence.)
Parts Used:
Water Inlet Valve with Quick Connections - 120V 60Hz
  • Michael from Clanton, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
The old condenser fan was rattling and driving everyone nutts.
I surfed partselect and read that a reader had a similar problem with a rattling fan. I then removed the back panel, after I had unplugged the unit, and was able to feel the slop in the fan shaft. I then watched the video of how to replace the fan and ordered the part soon after. The part arrived 3 days later! Easy to do. I was finished in 12 minutes and the fridge runs silently. The part of the job that took the longest was vaccuming the undercarriage. There was alot of dust! Couldn't have helped the efficiency on the fridge. Keep it clean.
Parts Used:
Condenser Fan Motor Kit
  • William from Salem, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench set
Was this instruction helpful to you?
Thank you for voting!
Failed to Run
Checked Overload Start Relay With Volt Ohm Meter&Replaced Them Easy And Simple Repair
Parts Used:
Refrigerator Compressor Overload and Start Relay
  • Lonnie E. from Canton, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan motor worn out and making noise.
Instructions were really clear and easy to follow. Hardest part of the job was moving the refrigerator away from wall after it was filled with holiday groceries.
Parts Used:
Condenser Fan Motor Kit
  • Andrew from Albuquerque, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Wobble in fan made a ticking noise.
Pulled out the Fridge. Removed the plug. Removed the back panel screws with nut driver. Vacuumed the coils & fan area. Disconnected the fan cable. Used a socket and thumb ratchet to remove the 3 mounting screws from its sheet metal bracket. Slid the old fan assembly out. Assembled the new Fan blade onto the new motor shaft and attached the adapter cable to the fan connector. Slid the assembly into place and reattached with 3 screws using socket and thumb ratchet. Connected adapter cable to fridge harness and plugged in the power cord to test the fan. With it working Quietly and knowing the the problem was solved, the back panel was reattached.
Parts Used:
Condenser Fan Motor Kit
  • Andrew from Fairport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
Very noisy operation
Removed and replaced the condenser motor fan kit. This was a very easy tear down and replacement of a bad component. Removed 4 screws to remove the bracket holding the fan motor kit pulled it out and replaced with the new unit (4 screws supplied) plgged in adapter cord (supplied) and re-installed took about 10 minutes.
Parts Used:
Condenser Fan Motor Kit
  • Mike from Coon Rapids, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
ice cutter grid was broken
It was easy to remove the old grid and replace it with a new one.
Parts Used:
Complete Ice Cutter Grid Assembly
  • harold from cleveland, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
After 5 years the pump gave out, but much cheaper to replace than buy new ice maker
1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at bottom of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace
Parts Used:
Ice Maker Circulation Pump w/Motor
  • Drew from Birmingham, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GI1500XHT9
61 - 75 of 130