Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Cord was not tightened enough by delivery crew.
PF alarm appeared on display. Noticed clicking when cord was moved. Had arced for some time and melted original block. New part slightly different. Only has 3 lugs, old one had six. Stack using washers provided. Take note of colors before disassembly. Use caution while working through access opening. The edges are sharp. Only tools needed are phillips screwdriver, deep socket for lug nuts. Nut driver optional. Hope this is helpful.
I first removed the top plate above the microwave door (3 screws), then I removed the plate containing the buttons and clock. The microwave has 3 relay switches and they are in a little holder. The holder was too difficult to remove so I just removed the bottom switch and replaced. The microwave started right up.
was told buy a repair person to check the door micro switches as it was a common problem. removed the top plastic air grill to get access to the screw that holds in place the control cover. After unplugging the unit, i took out the (2) screws that held in the switches and removed them (3). One switch was a bit melted so i tested it with a 12 volt battery and it was bad. Ordered a new one from Part select and got it fast . Works great .
After unplugging the unit remove the control face buy removing the screws. All three door switchs are on a bracket on the left. Remove the two screws holding the bracket in place and pull out. Disconnect the wires from the three switches and test each switch indivually to determine the bad one. I used a multimeter set on ohms.Replace the bad switch with the new one and replace all the wires. Reassemble the unit and you are good to go.
It is a undercabinet stovetop microwave. First had to take it down and unplug. Remove the top cover locate the door switch. Used neednose pliers to remove switch. Unplug two terminals.Plug new switch and use pliers to replace back @ same position.Plug in socket temporarily to see if it works.Afterwards if it works.Unplug and replace cover.Ready to be replaced back under cabinet.
replacing the fan on a convection oven (fan was making a vibration noise)
This was the first time replacing the fan. It is a lot easier to work in the oven compartment with the oven door removed, only two screws on the door and the hinges were released. I found that a couple of the screws were either rusted or stripped so I used a pair of pliers to remove the screws that were holding the diffuser in place. Once there was access to the fan I found that the fan was warped and that the blades were scraping against the back wall of the oven. The next challenge was to remove the retaining nut. I used a sheet metal screw to secure the warped fan to keep it from spinning. once I figured out that you have to turn the retaining nut to the right to loosen, it came off easily. 1/2" socket with extension. When I replace the fan I used two washers for spacers to make sure that the fan would not scrape the wall of the oven. Its been tested many times and the oven does not make that horrible sound anymore.
Have a double wall oven and the top oven would not shut off or broiler part would stay on and burn tops of food. Since bottom oven was not having any issues felt like it could Not be control panel so decided to try the temp sensor. Since replacing oven has worked properly.
Oven light stayed on & smelled like electrical burning.
Wife was cooking our thanks giving turkey, when an oder of burning was noticed. I walked over to the oven and smelled the area of oven light, it was bad. I turned off and unpluged oven. Got a screw driver, unscrewed 4 screws then noticed the burned switch from under the oven top. removed 3 wires, covered w/ elec. tape, and pulled oven light switch out front. looked at part number and ordered online. We were able to cook our turkey and enjoyed our meal.
The microwave door was stuck shut, because the p;lastic piece internal was broken...
first of all, ordered the right piece, second, brought the right handyman to help...getting the over/microwave out as one piece took some doing...then the cover of the microwave had to come off...once we got to the piece itself, it was no issue... then putting it all back together...took about two hours...he needed our assistance because of thew weight and the need to pull the units out simultaneously
Original Meat Probe insulation separated on the probe end
I searched the web for a replacement and Parts Select had a picture and part number for the exact same probe. I ordered the probe and it arrived very quickly. The problem was that the probe I received didn't match the picture as shown on the web site. Instead I received a probe that was a different color and the actual probe was about 2" shorter than the one I was replacing. I called customer service and was told that the probe I received was the new version that the older version was discontinued. If they had updated their pictures on the web site I would not have ordered the probe. Parts Select customer service did apologize for the issue and offered to have me return for a refund.
I will order from Parts Select but I will call first to verify that the item pictured is the actual item being shipped. Parts Select please update the part pictures to show the actual items being sold.
The door open lever behind the control panel broke so the door would not open.
As this microwave is part of a wall micro/oven combo, we removed the trim, slid out the microwave and tried for days to figure out how to release the microwave control panel. Through sheer force, we were able to release the lower half of the panel...enough to get our fingers, chopsticks and a flashlight inside to remove the broken lever. It took 2 of us to pull the panel out and replace the lever. I was hoping for a video online of how to remove that control panel but luckily we changed out the broken lever and it's back in working order! Glad we didn't have to trash and entire microwave/oven combo for one broken plastic part...it all works fine now.
Both oven bake and broil elements lost power suddenly at the same time.
Installation of the temparature sensor, one of the technician recommended parts took no time, just two screws and a snap off/snap on part. It did not fix the problem. I then replaced the main control panel, which requires more work, but didn't solce the ussue either. I then replaced the thermal fuse, which wasn't mentioned by tech support, and required much more disassebly of the top panels of the stove, with still no fix to the problem. I am waiting to replace the thermostat heat sensor unit, the only other part in the circuit controlling power supply, requiring removal of the stove top again,
Disconnected the power cord, removed the outer cover, shorted the two terminals of the high voltage capacitor with the blade of a screw driver with well insulated handle (very important to prevent a bad shock!!),;removed the plastic fan housing for access to the grounding screw and capacitor housing, installed the new capacitor with the reverse of the above steps (but don't reconnect the power cord yet!!} Now, the most important step of all, reach inside the oven and remove the mica wave guide cover, clean the oven walls thoroughly and clean the inside of the wave guide with clean cloth and water, sand to bare metal any carburized spots on the exit of the wave guide, cut out any carburized spots on the mica cover, replace the clean cover , or order a new one if necessary. It is OK to use the microwave without the cover while waiting for shipment of the replacement mica cover, but be absolutely sure there will be no food spatters on or near the wave guide opening.
Remove microwave from wall, removed outer cover which allowed access behind the control panel, was then able to take out the broken lever and with a little maneuvering was able to replace it with the new one. The whole process took less than an hour and was easy to accomplish.