Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Dryer would turn off too soon and clothes were not completely dry.
I removed the Moisture sensor from inside the dryer and installed the new one. Two wires are connected to the sensor and it is fastened down with two screws.
Popped in the new door catch! Tightened the hinge screws( which work loose and allow the door to droop. The reason the catch broke!) Also put red Loctite on the screws in an attempt to keep them from backing out again! Working great so far!!!
dryer stopped in middle of cycle and would not restart
followed the repair video and replaced thermal fuse and thermostat(recommend replacing both due to the problem could of resulted in either part being the cause),Repair went relatively easy.I also recommend to clean and vacuum the dryer while you have it all apart due to a lot of lint buildup and don't forget to unplug before servicing!Stay Safe!!!
You must disconnect appliance from the gas, water and vent to access the back. Remove the top of the dryer which then allows you to remove the rear panel by removing all screws, You may also have to remove 2 electrical connections to get this panel off. Now you have access to the air duct. To remove the air duct there are 3 screws inside the dryer and 2 screws on the lower part of the air duct. One of the lower screws is facing toward the inside of the dryer and you will need a 12"+ screwdriver to be able to remove. Once you do all that install the new part and repeat steps in reverse.
I removed the front, top and back panels of the dryer, installed belt around drum and through the pulley system so the belt was snug, replaced all screws and panels, and done.
Once we got the dryer out of the cramped where we could work on it, the project went a little quicker. I'd recommend using paper plates/bowls, that you label, to hold all the screws for each piece you remove off the back. It doesn't seem like it will be a lot, but we had at least 20-30 screws in 4-5 different sizes. Unlike someone else's install, we had to completely pull the white back panel off, as well as the main back cover, due to one screw holding the air duct from the inside of the dryer compartment (meaning we couldn't reach everything from the back). Getting this screw out was a challenge and seemed like a huge design flaw, but if you can't get to that screw, the old air duct isn't coming out. There are 2 other screws holding the air duct but they're easy to reach once the back panel is off. Once that was taken out the process was straightforward, we just took our time reattaching everything step-by-step. Now our dryer works like new.
Remove top lid by pushing tab on either side with a putty knife. Disconnect the 2 wire carriages on right. Remove one phillips head screw on each side that holds front panel to dryer body. Remove front panel by using flat head screwdriver to pry panel from body. Remove thermostat located on bottom right attached to front of motor on a plastic body by removing two phillips head screws. Disconnect wires and place on new part.
E66 Error code, Door Open. Dryer shuts off on high temperature
Unplugged dryer. Removed top panel (2 screws top back of dryer). Removed control panel ( Unplugged from control board and 2 screws) Removed front panel with door ( Unplugged light from control board, door switch at connector, and 4 screws) Removed Control Thermister from dryer exhaust blower housing located bottom front of dryer ( Unplugged 2 wires and removed 2 screws ) Installed new Control Thermister and replaced all screws and panels in reverse order. Note: Noticed connector for door switch seemed a little loose when connected correctly. Used electrical tape to reinforce connection. Plugged dryer back in and checked operation. Dryer has been used approximately 10 times since repair with no issues.