Wsher did not fill or run
Solved theprobel m by noticiing the HOT water filled the tub and it began to run when it was full. Figured out it was the solenoid valve. Ordered a new one. Simple to install and then it ran just fiine.
Parts Used:
Water Inlet Valve
  • James from Westwood, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slowly filled with water
The hot water side would fill quickly but the cold water filled very slowly. The seloniods and the valve is built all into one unit. I ordered and replace the part in no time at all. Now both hot and cold water fill quickly.
Parts Used:
Water Inlet Valve
  • Justin from Corpus Christi, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cold water selinoid didn't open
Removed three screws - Disconnected both inlet water hoses-Disconnected 4 electric clips-Removed internal hose connection from the same unit- Reverse order in assembly.
Parts Used:
Water Inlet Valve
  • ken from lakeville, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
washer filled with water very slowly
unplugged electricity from socket, turned water feed off at spigots, put plastic basin to catch water under place where hoses connect to washer, used pliers to turn disconnect hoses from washer and let them drain into basin. unfastened top screw on panel (only one) and tipped the old water inlet valve connections out over basin -- still spilled water onto floor, though. unfastened two screws holding old valve assembly to panel, set panel aside. loosened clamp screw on hose, moved hose off old valve -- a little water spilled out. held new assembly in similar position as moved wires one by one. used dry cloth to make sure electrical connections dry, then put hose back on, tightened clamp screw, fastened assembly to panel, fastened panel to washer, fastened hoses to valve, waited a half hour hoping any water on wires had dried, turned on water, washed clothes -- success!
Parts Used:
Water Inlet Valve
  • J. Michael from Champaign, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Inlet Valve wasn't allowing cold water into washing machine.
Made sure I had the right part. Inlet Valve looked just like the one on the website. Unpluged washer. Removed screws and water hoses. Disconnected wires from old Inlet valve and reconnected to new Valve. Disconnected water line from Inlet valve to washer tub. Reconnected water lines. Ran a test cycle. Works great. Wife very happy. Therefore, so am I.
Parts Used:
Water Inlet Valve
  • Michael from Olathe, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Washer was leaking. After removing the front panel I could see the leak was coming form the solonoid valve.
I removed the front of the washer then lifted the top up and swiveled it to the right. The solenoid is located in the back left. I remove the solenoid retaining screws from the the back of the washer, pulled the wires form the connectors on the top and bottom solenoids (hot and cold) and removed the defective valve. The new unit fit exactly! the total time to replace the solenoid valve was 25 minutes.
Parts Used:
Water Inlet Valve
  • Steven from Sterling, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dishwasher power shutdown mid cycle
Removed door panel to get to the electric control conponents and noticed a burned wire to one of the door microswitches. Ordered the door switch repair kit from PartSelect. Also, ordered and replaced the thermal fuse at the same time since it was only $12 and didn't know if that blew at the same time the switch cooked. I had the parts coming standard delivery (3-5 days), but they arrived the very next day. Parts included easy to follow directions.Job went pretty smooth and the dishwasher works again Good experience!
Parts Used:
Water Inlet Valve
  • Richard from Hampden, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old water valve assembly cold water solenoid valve was leaking thru.
Shut off water supply, unplugged washer power, removed supply hoses from old washer valve assembly, removed valve mounting plate and removed old valve assembly from mounting plate, diagrammed and disconnected hot and cold solenoid valve wiring and removed valve assembly outlet hose. Installed and connected new valve, performing the preceding steps in reverse order. pressurized new valve, verified valve function and checked for leaks and placed washer back in service.
Parts Used:
Water Inlet Valve
  • Richard from Paducah, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water would not shut off
First thing unpluged power cord from wall outlet, removed hot and cold water supply hoses.Then took out srew holding metal plate ,pulled plate out exposing valve, marked wires and diconnected.Pulled clamp and hose from valve.Pulled out valve and reinstalled new.Reconnected wires and hose.Installed screw to hold in place, reconnected hot and cold supply hoses.Plug unit back in. Job done.Washer works like new.
Parts Used:
Water Inlet Valve
  • Mark from La Mirada, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken water inlet valve
followed simple directions... no brainer.
just be careful - shut off water and unlug first.
Parts Used:
Water Inlet Valve
  • Ed from Chesterland, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad tube seals and bearings
Disassembled washer as per directions with seal kit. Removed inner tub. Cut both tub shaft bearing in half; punched out from outter tub. Installed new bearings using .5 inch threaded rod, washer and bolts. Installed new seal on inner tub shaft. Installed inner tube. Re-assembled washer.
Parts Used:
Single Washer Inlet Strainer
  • DAVID from SANDY HOOK, CT
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Socket set, Wrench set
1 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Valve Was Not On A Plate As Instuction
Had to take the back off to replace valve
Parts Used:
Water Inlet Valve
  • Ron from Golden valley, MN
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
washer kept filling up
I didn't expect a problem, but watched the video anyway, it was right on the money. Make sure to use a new clamp for the hose.
Parts Used:
Water Inlet Valve
  • R from ALTHA, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
no hot water
very well . it was very easy 20 min.
Parts Used:
Water Inlet Valve
  • James from Helenville, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Leg was mssing after move into new home.
Purchased x4 new adjustable legs. Leaned the washer back and held in place with block of wood. Loosened the two older front legs with an adjustable wrench because they had a locking nut and replaced with new legs. Repeated process on back side of washer. Once all the new legs were installed leveled the machine adjusting the legs if necessary.
Parts Used:
Adjustable Leveling Leg
  • Matthew from The Woodlands, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FA4161
76 - 90 of 123