Refrigerator would warm up while freezer got colder
Repair man thought it was the control board and an issue with a relay on the board. Purchased the new board but found out the board was fine, and it was the recirculating fan that would go out intermediately.
Tried ordering that part from Part Select since they have been great, but GE discontinued the part and their was not a replacement available. After much research, found the new replacement part number and ordered that, it went in quickly and for now seems to have solved the problem.
Removed the bad inlet valve and installed the replacement. Very easily done. The replacement part made the repair so simple and saved me a huge amount over calling a repair man. It did not take any special knowledge.
It was super easy! The glass came packaged and safe. Once I unwrapped it, I slid it in the firdge and it just popped into place. So super easy. And now we know for next time when taking it out to clean, (the reason it shattered in the first place) you should let the glass get to room tempurature before cleaning it with water or it will shatter! OOPS!
Freezer not getting cold enough to freeze ice cream
I took the advice off of your website about the only thing that will fix the problem is change the run capacitor. I felt assured that I would have a working refrigerator freezer after making this change. I was pretty disheartened when it didn`t solve anything. I was not going to take the new part back out after the small challenge of putting it in. The next day I found out how to test the old capacitor and it was still good. I will just have to eat the $49. I did learn not to take advice from a website even if it seems like a sure thing
Crisper Pan Glass accidentally dropped and crashed!!!
Search online and came across PARTSELECT website!!! this is amazing when I opened the website and see a labeled drawing, so I know what part number to order, it arrived on time and when I install it fits very well, one lesson I've learned is whenever you removed this glass in the chiller box you have to reinstall the glass properly by inserting one of the side to the insert slide of the chiller so it will not move! I'M VERY HAPPY!!!! THANKS!!!
Received replacement part. There is a cover over the ice box latch. Pried it off with a screwdriver head. Took the broken latch off replaced new latch to cover and replaced on the door.
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor. Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
We broke the glass shelf above the vegetable bins, when we took it out to clean it.
I went on line, found PartSelect, located the diagram for our model, selected the part and ordered it. The part arrived in about 5 days, well packaged. We removed it from the packaging, and installed the new shelf. Extremely easy process. The exploded diagram on the web site allowed me to make sure I was ordering the right part.
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Literally turned off the water to the refrigerator, disconnected the lines from the back and took one screw loose from the inside of the unit. Slid out old filter connection and slid in the new one and did reverse process.
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.