DBXR463EB2CC General Electric Dryer - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Cracked air duct
Two screws under the dryer door then the top comes off.Then two screws hold the front on come out. 4 screws top is off and front is off the rest is no problem.
Parts Used:
-
Forrest from Mays Landing, NJ
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer won't start
(1) unplug the power from outlet. (2) unscrew the 3 screws. (3)slide the front instrument panel slight right to remove it. (4) flip over the panel (5) remember the wire colors and their connections, and remove 3 wires (6) pull up the metal tab on the start switch a bit to unlock it and turn counter clock wise to remove the switch (6) do the reverse steps to install the switch.
Parts Used:
-
Jianping from BELLEVUE, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Low heat
I bought the Heating Element and Housing together so that I would not have to stretch and run the coils and to save time!
1. I removed the two screws that hold the top down by opening the dryer door and removing the two screws at the top of the door opening. Then I pulled the top off.
2. Then I removed the two screws on the top inside of the dryer on the left right and took the front off.
3. Next I spread the dryer open a little and pulled the drum out while pushing the belt off the back of the drum.
4. Then I removed the screws to the sensors and removed them from the housing.
5. Then I removed the four screws holding the heating element housing to the back of the dryer and took it out and put in the new peace.
6. Do everything in reverse when putting the dryer back together.
1. I removed the two screws that hold the top down by opening the dryer door and removing the two screws at the top of the door opening. Then I pulled the top off.
2. Then I removed the two screws on the top inside of the dryer on the left right and took the front off.
3. Next I spread the dryer open a little and pulled the drum out while pushing the belt off the back of the drum.
4. Then I removed the screws to the sensors and removed them from the housing.
5. Then I removed the four screws holding the heating element housing to the back of the dryer and took it out and put in the new peace.
6. Do everything in reverse when putting the dryer back together.
Parts Used:
-
Larry from Naples, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original terminal grounding block melted for unknown reason.
Unscrewed the old, screwed in the new making sure wires matched up same as before. Reset my breaker and works like new again.
Parts Used:
-
Manuel, J from MCALESTER, OK
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When moving the dryer there was a loud pop and the dryer circuit breaker tripped.
When the dryer was installed last year by the dealer, one of the hot leads was not screwed down tightly. Over time the screw loosened and began to arc causing the plastic holding the screw to melt. When I moved the dryer the hot lead fell off and hit the terminal block cover shorting out the dryer. I was able to locate the exact terminal block I needed with their helpful dryer section diagrams. The part came in the time they said. I took off the old terminal block with just 2 attached screws. i kept track of which screws held the hot and neutral conductors and the ground before I removed them. I was then able to slide on the dryer wires and attached the home conductors. I put on the cover plate, turned on the circuit breaker and it worked.
Parts Used:
-
LARRY from HAMILTON, OH
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bulb dead
-
Carole from Wynnewood, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bulb was intermittently working
Inspected door switch operation and was working properly and simply looked for bulb in the dryer drum housing and located it immediately above the door opening,unscrewed it and noticed the broken elements inside. The bulb is a 10w/120V. Installed bulb problem solved.
Parts Used:
-
Peter from LEOMINSTER, MA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burnt out bulb
-
Jeffry from ROCKVILLE, MD
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
on /off switch would not work
remove 3 screws from back of top panel unplug wires from back of switch and twist out switch and replace same reassemble panel and plug it back in
Parts Used:
-
Robert from WOBURN, MA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer didn't turn on
The part came today…and I installed it in 10 minutes. The only time consuming part was locating a torx screwdriver which was needed to remove the panel.
Lifted the panel, extracted the existing switch and
disconnected the wires and used a flathhead screwdriver to lift off the existing switch. Reconnected the new piece, and voila my dryer worked!
Your site is great!
Lifted the panel, extracted the existing switch and
disconnected the wires and used a flathhead screwdriver to lift off the existing switch. Reconnected the new piece, and voila my dryer worked!
Your site is great!
Parts Used:
-
Rachel from Monsey, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer Would Start Automatic Without Using Start Switch
Remove top control panel, disconnected wire from old switch to new switch (remover 1 wire at time so it would not get mixed up)twisted old switch out inserted new switch and replaced control panel now works like it should. I thought it might would be a safety issue is why I replaced it
Parts Used:
-
MATTHEW from LIBERTY, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bulb
Open dryer door, reach in at the 12 o'clock postion
on the inside is the bulb.
on the inside is the bulb.
Parts Used:
-
Mark from Monroe Township, NJ
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Start Switch Replacement
It's no surprise that GE would use cheaply made parts in such a mass produced product, but it was irritating to see the start switch fail just fourteen months after purchasing the dryer. I am glad that a little thought was put into an easy snap and twist installation of the control panel switches. The original switch failed, due to arcing and pitting of the contact points no doubt, and the local parts house didn't even recognize the part, let alone have it in stock. Thanks to PartSelect.com I could have the part in just a couple of days!
The panel comes appart with just four star driver screws on top, but an allen wrench will work also. Wire jumpers with spade connectors are pulled apart and reattached with needle nose pliers.
In the mean time to keep the dryer operational, I did some creative "re-assigning" of some of the control panel jumper wires using the switch that controled the "Wrinkle Care" setting as a temporary Start Switch as it had the same current handling limits. By the way before attempting such a temporary bypass setup, consider not voiding any warrantee arrangement still applying to the product and have some basic electronics and safety knowledge, study the provided schematic well attached to the back panel and remember to write down all of the original wire connections. And when in doubt, calling a qualified GE appliance repair person is your best and safest bet.
New part went right in in about 15 minutes with original wiring restored and double-checked and the dryer is running right on que again.
Thanks PartSelect.com!
The panel comes appart with just four star driver screws on top, but an allen wrench will work also. Wire jumpers with spade connectors are pulled apart and reattached with needle nose pliers.
In the mean time to keep the dryer operational, I did some creative "re-assigning" of some of the control panel jumper wires using the switch that controled the "Wrinkle Care" setting as a temporary Start Switch as it had the same current handling limits. By the way before attempting such a temporary bypass setup, consider not voiding any warrantee arrangement still applying to the product and have some basic electronics and safety knowledge, study the provided schematic well attached to the back panel and remember to write down all of the original wire connections. And when in doubt, calling a qualified GE appliance repair person is your best and safest bet.
New part went right in in about 15 minutes with original wiring restored and double-checked and the dryer is running right on que again.
Thanks PartSelect.com!
Parts Used:
-
Michael from Tallahassee, FL
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
3 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
spring loaded start switch stopped.
removed 4 screws from top of control panel. pulled 3 knobs off. removed face cover. unplugged damaged unit. twisted unit to right and removed. installed new unit. plugged in wiring. replaced panel. replaced screws and knobs.
Parts Used:
-
stephen from Lake Lure, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer start switch wouldnt work.
Turned breaker off in electrical panel. First removed all knobs.Removed four screws and removed panel.Removed wires from terminals and switch twisted off. Installed new switch,replaced wires on terminals.Put panel back in place with four screws,then replaced knobs.Turned breaker back on and started dryer with start switch,worked great.
Parts Used:
-
Pat from Kingsport, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!