couldn't get the wire connection anywhere after we bought the heating element.
we received the two heating element wires in 3 days and connected the heating element with no problem works great.
Parts Used:
Heating Element Connection Wire Kit
  • Betty from Erie, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer stopped heating
(Always unplug dryer before making any repairs) I opened the dryer and checked the heating element. Making sure that the connection was good and nothing was damaged, I determined the problem was overheated wires. They melted and lots connection. I replaced them with the heating element wire connection kit. Easy to install and simple to get right. I cleaned the dryer again with a vaccum cleaner, removing all the lint, and checked the vents, making sure they were clear...I turned the breaker on (it was tripped when the dryer overheated)and everything worked great.
Parts Used:
Heating Element Connection Wire Kit
  • Joseph from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer was not drying clothes with-in 40 minutes. Found lint guard was not sealed properly at base, exhaust hose full of lint.
This model you cannot lift the top lid without breaking it. Removed the exhaust hose and back of dryer. vacuum out the dryer and hose to remove the excess lint. Remove screws from the lint guard mounting. Loosen and remove 4 screws that hold the lint guard in place. The seal at the base of this assembly was missing the seal around the discharges fan. Remove seal with putty knife. Use a small brass wire brush to remove as much as you can. Vacuum area. Reinstall the lint guard assembly, start at the top, gently life and push assembly up and in. You should be able to determine how far. Start the bottom 4 screws, tight them. Check fit. Then put the screw back in on the lint guard on the top of dryer. Once you have completed this connect exhaust hose. Start dryer, check the dryer exhaust vent that is outside. If the flow is good, WELL DONE!

Recommendation: Check this assembly by removing the back of the dryer approximately every 6 mos. for lint build up. Not doing this may increase the risk of fire.
Parts Used:
Dryer Seal
  • Charles from Rupert, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no heat when drying clothes
My husband changed the part but part select was very helpful. With their free repair help site it made repairing a breeze! We will use parts select again and again. I did order all the parts we might have needed and only needed one. Now I will return the others.
Parts Used:
Heating Element Connection Wire Kit
  • Tracey from Marion, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Was this instruction helpful to you?