no refrigator cooling
First i pulled the electrical plug from the socket so the refrigator was off than I removed 5 screws (3 of those holding the ice maker). pulled the icemaker toward the front and removed it I than took off the back of the freezer panel,(the back panel was removed by pulling the top of the panal towards me it came right out of the freezer) I removed an additional 2 screws holding the evaporator fan motor. Than I used pliers to squeeze the mounting bracket tabs (white tabs BOTTOM OF MOTOR BRACKET). I then disconnected the electrical FAN MOTOR PLUG and removed the motor. i than pulled the fan blade from the motor (fan blade is only a pressed onto the motor shaft.I than pressed the fan blade back unto the fan motor and reversed the above directions
Parts Used:
-
JOHN from WILLISTON PARK, NY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
change evap.fan motor
unplugged the fridge removed the shelf, remove the rear wall to access the motor removed the 2 screws holding the motor and unplugged motor from harness, then unplugged the groung wire .then put it back together up and running in 15 mins.
Parts Used:
-
William L. from Delanson, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers