Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.
Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.
Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.
It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
The evap motor failed (no air movement inside of refrierater
Removed screws from cover tested for power to motor found power was on to motor but motor did not work. I went to your web site was able to locate part in about 5 minutes . Even with over night shipping the part came to about $50,00, far cheaper tha a service call would have been.
Unpacked, inspected, found two minor defects in the form of two tiny slivers along the seal edge which I cut with a small scissor, laid the seal down on the kitchen table, applied heat to the deformed areas and reshaped them with my fingers, heated the entire seal lightly, removed the old seal starting at the right hand upper corner using my fingers, installed the warm seal starting at the top corners by pushing it in its slot making sure the outer lip stayed out of the slot and worked my way around. I believe that the heat from the dryer made it pliable and easier to manage.
Remove the light cover. Use a flat head screw driver to push in the tabs on the back of the program mount and pull down to expose the computer board. The Thermistor is clipped on under the vent holes on the right side. Cut both wires to remove the old thermistor strip a 1/4 inch off the remaning wires and the new thermistor wires twist both ends together crimp on the wire caps snap in the new thermistor reinstall the program board until the retainer clips snap into place, slide the light cover back on.
Removed the drawers and shelf unit above the shelves. Installed the new rail and put the shelf unit and drawers back in. Less than 5 minute repair. Very fast delivery of part and reasonable pricing.
Unsnap damper louver cover using only your fingernails at bottom. Remove two phillips screws from damper cover. Remove styrofoam molded insulation. Squeeze electrical connector to release latch; unplug connector. Release latches on both sides of damper control while gently pulling on damper control unit to remove it. Install new unit by doing above steps in reverse. Damper door may move when electrics connected; keep fingers clear. Amana would not honor our extended warranty that we paid $65 for, saying that noises are not covered. Im glad that Partselect supplied the part quick and and a great price. The frig is quiet for the first time in 2 years!
Ok, pretty easy repair when the parts are correct (first part was faulty, parts select quickly sent me a new one)
First is removal, these tubes are in there very tight, they can be pulled out but weaken the lines and it is not likely to work without severly stretching the line to the point of breakage, if you have to cut them do so carefully and take off as little tubing as possible as you need the length to feed from top to bottom.
Once you have cut all the lines, or pulled them out (I was able to get 2 out without cutting) then make sure the edges are smooth, attach the inlet valve to the plate and just push them tightly into the new valve making sure you route the lines correctly.
Turn everything on and run the water line to see if it works. If no leaks, screw it back to the refrigerator and you are good to go. Takes maybe 20 minutes at most.
Remove cover inside frig at rearwall top with screw driver. Remove phillips screws holding unit in place. Unclip connectors ,and replace in reverse order.
I used board levers to do one side at a time.Kinda tricky, but you can hoist up fridge high enough to replace wheels. take your time think it out and be safe . Make sure you use saftey boards to support load to protect yourself==good luck A small mirror may help to see how the rollers alien in the supports.
Inside the food section above the top shelf behind the light in the back, remove the lid from the cover in lifting from the lower edge no tools necessary here. Remove two screws with Phillips screw driver remove entire housing inclusive Styrofoam insert. Unplug damper Control Unit. Remove two screws and remove damper control unit and replace in reverse order. Finally that refrigerator is quiet, I should have done this long time ago. Unbelievable this is the second part I have to replace on this expensive refrigerator.
Freezer would get cold at bottom and some of the refrigerator. Took of freezer back panel and located freezer fan. Took a meter and saw power was getting to it, but not working. Removed fan and replaced with new on, working like a charm. Cold air was not circulating enough throughout the unit because fan was not working. It was not the thermostat or adapter control.
Door was not closing with any positive feel and would often pop open when left door was shut.
Popped out old gasket and popped in nwe one. This is where things get interersting, the new gasket Does work as well as the one I replaced. I think the maganet is not strong enough. If anyone has had the same problem please let me know. This model ( Maytag- French door ) has been a lemon.
Our refrigerator was too cold as the thermistor seems to have gone
It was great. We replaced the thermistor A little difficult to get to the thermistor but once we found it five minutes. My refrigerator seems happy but we will monitor it and see.