EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
Back
Back
Back
Keep typing for more specific results...
Keep typing for more specific results...
Models > 2539280210 > Instructions

2539280210 Kenmore Freezer - Instructions

All Instructions for the 2539280210
31 - 45 of 71
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
I Lost The Key
I order another one thanks
Parts Used:
Freezer Door Key
  • VICKIE from DAWSON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
Evaporator Fan Blade
  • gary from ARANSAS PASS, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Pushbutton light switch failed.
Needed a Phillips head screwdriver to remove bottom plate (kick panel). UNPLUGGED FREEZER. Removed plate pulled switch out through the mounting hole and unhooked the two electric wires. Placed wires on new switch, pushed wires back through the hole and seated the switch. Plugged in the freezer and opened the door - magic, the light came on. Replaced the front kick panel (hardest part was to line up the plate holes with the holes in the mounting bracket).
Parts Used:
Door Light Switch
  • Arlee from HOUSTON, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Followed the instructions that were sent and repair was easy.
Followed the instructions
Parts Used:
Freezer Door Gasket
  • Glenn from CHAPPELL HILL, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost Timer
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. The video that was on-line helpful also.
Parts Used:
DEFROST TIMER
  • DAVE from LOS RANCHOS, NM
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
End cap for side door shelf broken
Both end caps were missing on the door side bottom metal shelf. succesfully installed no tools needed
Parts Used:
Shelf End Cap - Right Side - Tilt-out
  • wissam farhat from medley, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Missing key
After removing the key from its shipping package I pushed it into the freezer locking slot and turned it to lock and unlock the lid and then removed it. I had no problems with this fix. Of course, I am an older gentleman with a lot of experience in repairs around my house,as well as other houses. I am sure that a less experienced person may have more of problem with this type of "repair".
Parts Used:
Freezer Door Key
  • John from DUNBAR, WV
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I knockedoff the door light sensor when I dropped a frozen jug of ice
I removed the plate (recommend using a magnetic phillips head screw driver to remmove screws which are recessed). I removed the old part and pushed the new part through the hole and carefully reached in behindto attach the wires to the new part.
Parts Used:
Door Light Switch
  • Rob from HILLSBORO, NH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not freezing.
I removed the compressor start relay and replaced it with the new part. Initially it did not work. When I checked my work, I had to tighten the connector on the new part. Once I made the correction, the freezer is freezing normally again.
Parts Used:
Compressor Start Relay
  • Andre from ANDERSON, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Parts Used:
DEFROST TIMER
  • Thomas from GRANBURY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils were freezing up. Defrost cycle not working
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Parts Used:
DEFROST TIMER
  • Stirling from FORT WORTH, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer just quit working. I could turn thermostat off. Click ever few seconds would stop..I figured the thermostat was good compressor not starting
First unplug it and pull away from wall to gain access to the Rear of freezer.
From the rear of the freezer. You can clearly see the compressor.....I had to lay in the floor. Best way to see what your doing .
Attached to the side of the compressor
Is square cover over the start relay..it has a metal bail that retains the cover. Simply remove the strap with a flat blade screwdriver the cover can then be removed. A flashlight and screwdriver is all I needed
The switch body plugs onto the compressor with pins or blades. Mine broke in a few pieces by the time it was completely removed. The start switch has very tight connections so its a bit of a struggle to get it off. ..stick screw driver behind it and try pry evenly until its off..secure new switch on the pins and push it in ..there is one single wire attached to the start switch no confusion there.install cover and its retainer and its done..
Parts Used:
Compressor Start Relay
  • kenneth from Ayden, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Just lost key
No repair. The key fit!
Parts Used:
Freezer Door Key
  • Toni from Little Rock, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door wouldn’t stay shut
Purchased gasket from parts plus installed it and door still won’t stay shut without duct tape plus the frost is building up really bad looking for another parts store to get problem fixed
Parts Used:
Freezer Door Gasket
  • Angela from ORLANDO, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lost original key
Brought replacement key works just like original I thought it would be metal from reviews but it was plastic and still works perfectly
Parts Used:
Freezer Door Key
  • katrina from EAST ORANGE, NJ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 2539280210
31 - 45 of 71