Models > 25331432107 > Instructions

25331432107 Kenmore Refrigerator - Instructions

All Instructions for the 25331432107
16 - 30 of 168
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The bottom of Refrigerator would not get below 48 degress. Freeezer was working fine.
First I unplugged fridge. I then removed cover that keeps fan protected. I then removed 2 screws that hold the evaporator motor in place. I then removed 3 wires running to motor. Very easy to remove, just pulled connections apart. I then replace the old motor with new.

The Sears repairman wanted to charge me $359 to repair. I did repair for under $40! Amazing what you can save if you have the time and knowlege to do it yourself.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Jeffrey from Bridgeville, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
25 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Parts Used:
Defrost Timer - 60Hz 120V
  • Miles from Longview, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
22 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Socket short
- Unsnapped old light socket from top of Frig
- Disconnected elect wires
- Reconnected elect wires to new light socket
- Snapped new socket in place
- Done in less than 2 min.
Parts Used:
Light Socket
  • Rebecca from Gautier, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer is working but not the refrigerator.
Removed the cover inside the freezer. Found out that the motor/fan was not working. Ordered through PartSelect. Got the parts in 3 days. Installed it for less than 30 minutes. Very easy. It saved me hundreds of dollars. We considered buying a new fridge but not anymore. , it only cost me $70 including shipment charges. (Make sure you unplug the appliance first before opening the cover. Remember safety first.)
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Neptali from Groton, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench set
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was trying to cycle compressor on, but each time the compressor started, it would stop due to the thermo breaker would open. The fans continued to run, so I figured it was starter relay.
Moved the refrig. out, removed the four screws that held the lower access panel in place. Disconnected the power cord. Removed the retainer clip wire and pulled the relays from the compressor socket. Separated the relays and installed the secondary relay on the new starter relay. Reinstalled the starter relay assembly into the compressor socket. Plugged the power cord in and listened for the compressor to cycle on. It cycled on and continued to run. Turned the power off and reinstalled the retainer clip wire. Reinstalled the access panel and plugged the power back in and left the refrig. run overnight. Checked temperature and also started the ice maker. Everything was normal by morning.
Parts Used:
CONTROLLR
  • Harry from Rockwall, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would not start.
After earlier determing that the starter switch was at fault, I removed the cardboard lower back panel, shut off water to the ice maker, removed water line. The plug to the compressor containing the switch and capacitor was held on by a spring clip, removed clip pulled wires from old switch (Here needle nose pliars are handy as the spade clips on the 2 wires have their own locking clips) replaced switch and all wiring, tested unit and problem solved.
Parts Used:
CONTROLLR
  • Raymond from San Antonio, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator not cooling n freezer iceing up.
This fridge is less than 2 years old really disappointed with frigidaire quality. Had a appliance repair guy diagnose the problem and paid $45 for the service call but decline for him to do the repair for $320. Remove the cover 4 screws holding it on top of fridge the defrost timer is inside 2 screws and you just unplug and replace with a new one. The defrost thermostat is in the freezer compartment, remove the ice maker if equiped then remove back cover, cut out the old thermostat n crimp in the new one. So far the fridge is working but still not getting as cold as before but good enough to keep things safe. Thanks to partselect.com i saved a bunch of money doing it myself.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Haley from Antioch, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side warm. Freezer was ok.
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and replaced unit. Works fine ever since.
Parts Used:
Defrost Timer - 60Hz 120V
  • Doug from Folsom, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door gasket was cracked and falling apart
Watched your video, used a stiff putty knife to pry the gasket loose.Cleaned the surrounding area and pushed the new gasket in. I used a plastic body moulding tool to make sure the gasket was sealed. Very easy repair!
Parts Used:
Fresh Food Door Gasket - White
  • MICHAEL from BAYTOWN, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Food compartment not cooling, freezer working well.
Fantastic!
Sent in a brief description of problem and model number. Reply and description of other customers experiences guided us to the exact problem.
We ordered the part on Friday and it was here on Tuesday.
I prepared the freezer compartment for the removal of the old motor and on Sunday husband installed new Evaporator Fan Motor.

It works and is cooling like it did when it was new.

This has been a great experience as all repairmen wanted at least 60.00 to just come out and determine what the problem was. I can only imagine what the final bill would have been.

This was easy and inexpensive.

Thanks for all the help.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Mary from Kenmore, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer door gasket with a holes
/
Parts Used:
Freezer Door Gasket
  • Karine Lepold /BM CARGO from Miami, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
Parts Used:
Light Bulb
  • Lise from CEDAR GROVE, NJ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • charles from parker, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Starter went out.
Unscrewed the lower back cardboard panel and removed it. Unplugged refrigerator. Reached in and took the metal piece off that keeps the starter from coming off. Pulled the starter off the compressor. Unplugged the starter from the power line. Replaced starter. Hooked power line back on. Hooked starter to the compressor. Put the metal piece back on to hold in place. Plugged refrigerator back in. Put back panel back on.
Parts Used:
CONTROLLR
  • Stuart from AMES, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Denver from BLAIRSVILLE, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25331432107
16 - 30 of 168