Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Parts Used:
Defrost Heater
  • Edward from Sykesville, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Donald from Strafford, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Socket set
Was this instruction helpful to you?
Thank you for voting!
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Robert from Batavia, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Barbara from Apollo, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
Was this instruction helpful to you?
Thank you for voting!
Fan motor stopped working
Well I could what laid on the floor and replaced it but I didn't I emptied refrigerator laid it over change the motor then stood it back up actual work about three hours
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • john from white pine, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Not cooling properly/ door divider getting hot.
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Timothy from Granite City, IL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Wrench set
Was this instruction helpful to you?
Thank you for voting!
not cooling
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend trying this repair unless you are a pro.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • larry from indianapolis, IN
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!