Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
I went on the web to search for parts, did my screening of companies, and chose Partselect.com They gave me accurate information, very nice, and double checked the part numbers, and the latest replacement part. I received it in a couple of days, followed the directions, and it's working just fine! I saved a lot of money through Partselect, instead of buying a new refrigerator. NICE JOB Partselect!! Thanks, Michael
The old door gasket was hard and frequently didn't seal and caused evaperator to ice up and contents of freezer to thaw out.
Using a nut driver on a cordless drill I took out the screws that held the metal strips on, which held the seal in place. I installed the new seal with a hand driven nut driver so as not to strip the screw holes in the door. It came out well and the new seal works very well. Getting the seal positioned properly was the most tedious part.
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.