Roper Dehumidifier Bucket Water Level Switch
PartSelect Number PS992307
Manufacturer Part Number 1188814
This part is for your dehumidifier. The bucket water level switch is used to prevent water overflow when the bucket is full. You will not be able to tell if the switch has failed just by looking at it. You will need to perform a continuity test. This will determine if a continual electrical path is present. If you notice that dehumidifier will not run even when the bucket is empty, it might be due to the switch needing to be replaced. To access the part, you will need to remove all the outer housing. The switch is located in a plastic holder found on the inside wall.
Installation Instructions
Lester from Brazil, IN
Push on connectors and switch housing were different
The switch housing was not exactly the same for easy snap in. I removed the actual switch and installed it into the old housing. Then I found that the male pins were larger than the old ones. I chose to clip off the female connectores, strip the wires, and solder the wires to the pins on the switch. It was easier for me than attempting to change the push on connectors. For me, the actual switch was what I wanted and I fixed it my way. It was easy to do however some folks may want to change the push on connectors. Works great and saved me hundreds of dollars. Thanks.
Read more...
Roper Dehumidifier Appliance Types
Popular Roper Dehumidifier Models
Below are the most popular Roper Dehumidifier models we have. Enter your model number in the search box to find your model.