David
March 7, 2023
On the diagram the part number is Ap3902370 but that part doesn't look like the part I removed. Thje compressor overload protector is is open even when cold
For model number GLORT183TDWB
Hello David, thank you for contacting us. The start device, part number PS1145197, is a compatible device for your model and can be interfaced at the location mentioned in the diagram. Faulty start devices can cause the compressor overload protector to open even when the compressor is not heating up. You may need to replace the start device, part number PS1145197, and the relay switch, part number PS833023, as they are responsible for starting the compressor. We hope this information is useful!
Hello, what is the purpose of PS1145197, 5 speed start device...Thanks
For model number LFFU1465DW5
Hello Mike, thank you for the question. The purpose of the start device is to apply energy to the starting winding of the compressor until the motor gets up to speed and then disconnects energy to the starting-winding while the run-winding continues to receive energy until the thermostat opens. We hope this information helps!