RAD-123A LG Air Conditioner - Overview
Models starting with RAD-123A
Click on the best match to narrow your results.
Keep searches simple, eg. "belt" or "pump".
Remote Control Assembly
PartSelect #: PS11760970
Manufacturer #: AKB73795706
This remote control is a device for adjusting your air conditioner settings. It requires two AAA batteries for operation. A malfunctioning remote control may have unresponsive buttons or signs of phys...
$46.34
In Stock
Room Air Conditioner Installation Kit
PartSelect #: PS7784777
Manufacturer #: 3127A20074Y
The installation kit contains the hardware you need to install the room air conditioner.
$60.51
In Stock
Clamp,Spring
PartSelect #: PS3522762
Manufacturer #: 3H02932B
This spring clamp is designed for your room air conditioner. This clamp holds the fan blade on the motor shaft so it can rotate during operation. If your fan blade is wobbling on the motor shaft, you ...
$8.55
Special Order
REMOTE CONTROLLER ASSEMBLY
PartSelect #: PS12079512
Manufacturer #: AKB73016015
$40.02
Special Order
Room Air Conditioner Fan Bracket
PartSelect #: PS3524525
Manufacturer #: 4960A20005A
No Longer Available
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken fan axial blade
Unscrewed the unit from the exterior case pulled out the unit unscrewed the 4 screw that hold the fan shroud carefully unscrewed the coil pulled back unclipped the axial fan clip gentlyhit with rubber mallet replacement of new fan replaced clip
15 minutes best investment of 20 bucks as apposed to 400 $
15 minutes best investment of 20 bucks as apposed to 400 $
Parts Used:
-
John from HARLINGEN, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
8 of 13 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Kenmore Air Conditioner Remote Broken
No repair. Just a new remote controller assembly and it works fine.
Parts Used:
-
Patricia from UPPR CHICHSTR, PA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor mount broke due to imbalance caused by mud dobber nests.
Pulled PTAC out of wall sleeve, unhook wire harness from control area, remove condenser shroud and motor and fan blade all at the same time. Replaced motor bracket and re-installed in reverse order.
Parts Used:
-
Travis from LOUISVILLE, IL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!