Your coupon for will be reflected when you check out!
✖
Your coupon for
✖
Hello!
You're visiting the PartSelect site in U.S.
Would you like to shop on the Canadian site?
Stay on this site
Go to Canadian site
JVB37H1BB General Electric Range Hood - Overview
Save your modelModel Saved!
Save your model for later to make things easier.
Model has been saved to My Models. If you're not signed in, your lists are available on this device and will expire within 30 days.
Model has been saved to My Models.
This part is the replacement membrane switch for your range hood. It is approximately 4 inches in length, and the part of the switch that you push is black in color. The membrane switch or downdraft v...
Ask our experts a question about this model and we'll get back to you as soon as possible!
2 questions answered by our experts.
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Rod
April 28, 2022
Has power, but burners do not heat up.
For model number JVB37H1BB
Hello Rod, thank you for your question. Please have a look at a link from our site https://www.partselect.com/Repair/Range-Stove-Oven/Cooktop-Element-Not-Heating/#Surface%20Burner%20Terminal%20Block%20&%20Receptacle. We hope this helps. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you.
Was this helpful?
Thank you for voting!
Maria
October 23, 2024
When I turn on any burner it beeps and I get a red flashing F on all switches to burners and an F112 code above the timer. No burners will come on. The front left burner went out a while back but now the other 3 are out. What could be the problem?
For model number JVB37H1BB
Hi Maria,
Thank you for your question. The F112 error code indicates that the front left burner has failed. To see if you can remove the code, cut power to the stove for 60 seconds and plug it back in. If you still have the same issue, then you will need to replace the front left burner. We hope this helps!
Was this helpful?
Thank you for voting!
< Prev
1
Next >
✖
Ask a Question
Ask our experts a question on this model and we'll respond as soon as we can.
I pulled up the wires that the membrane switch hooks to and connected the new one with the new sensor pushed them down the opening. Took the sticky paper off the up and down button and stuck it too the indentation where it goes and there you have it as good as new! Works great!
In the process of diagnosing the problem, the circuit board burned out and the fan switch broke. Had a great deal of difficulty removing the unit. Had to disconnect gas line to range top and remove it first before I could remove the downdraft unit. I still had to get some crazy glue to hold down new microswitch on top of the unit. It
... Read moreis finally working fine now.
Received membrane switch quick after I ordered it. Connected switch to downdrafts system in less than 15 minutes. Tested system to make sure it worked. very happy with partsselect shipped quickly after ordering.