The end caps of the door shelf bracket broke
Put the end caps on the ends of the shelf bracket and returned the bracket to the proper place in the freezer.

Just wanted to add that the service and helpfulness to get this part for a freezer that is close to 30 years old was super. After almost 30 years, this was the first thing to go wrong with this freezer. We did not expect to be able to find this little part for repair but thanks to fantastic help, our freezer is in good shape again. Thank you !
Parts Used:
Door Shelf End Cap Set - White
  • Melvin from Manning, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
20 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer stopped freezing food.
I unplugged electrical cord to the freezer. I removed the cover to the relay and load protector. I labeled the wires and made a diagram on the proper placement of each wire going to the relay. I unplugged each wire and removed the relay. Then I removed the load protector. I installed the new load protector and new relay. I placed the wires on the proper terminals of the relay. I replaced the electrical cover to the relay and load protector. I plugged the electrical cord back in the electrical outlet. My freezer started working again. I placed several bottles of water in the freezer to make sure the freezer was working properly before I restocked it with food.

Thanks again for the help. You just saved me about $400.
Parts Used:
Overload Protector Relay
  • FREDDIE from WHITAKERS, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
19 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Erratic light.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
Parts Used:
Door/Light Switch
  • D KIRKE from CORVALLIS, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
While defrosting freezer tossed the drain plug with ice and water into the sewer system.
Opened mailer and bag and place the drain plug into the drain. fit perfectly. In fact it is better than the one lost since the original needed a screwdriver or tool to remove the plug. This one has a flang or finger turner on it so that it can be removed. Also, does not interfere with items in bottom of freezer.
Parts Used:
Interior Drain Plug
  • paul from LISLE, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!