Evaporator Thermistor Sensor
PartSelect #: PS2359468
Manufacturer #: 5304471383
This evaporator thermistor sensor in your air conditioner measures the temperature of the evaporator coil and adjusts the cooling process accordingly. It is typically attached to the evaporator coil, ...
$32.55
In Stock
Questions And Answers for FFTH0822Q12
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Failed Control Panel Board/ No Heat,Cool, & Fan Control
Remove power cord from receptacle, remove filter, two phillips screws to remove at each side ( located where filter slides into), from the top of unit slide your hands down 2/3 on each side press in on metal cabinet while pulling out on plastic face/cover, lift up facial cover ( I bump across on top of metal sleeve unit to dislodge top of
... Read more
facial cover from metal sleeve), disconnect wiring connector, remove 4 screws holding plastic cover and pc board, remove old pc board, clean plastic cover, install new board and plastic cover, install 4 screws, re-connect wiring, place wiring connector as well as wiring excess back inside unit, start at top and align facial cover, slide cover into place, bump cover in position on metal sleeve at sides and bottom, re-install 2 screws, re-install filter, re-attach power cord to receptacle. If unit has toggled to celsius, hold temperature up and down buttons together for 3 seconds, unit will toggle to fahrenheit.
Read less
Parts Used:
-
Gregory from Providence, RI
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!